Wiring worksConnection of the 2-way valveDescription No. of wires Min. / Max. current Thickness Supply ScopeMotorized 2-way valve to shut offUFH loops during cooling. 2+ground 10mA / 50mA > 0.75 mm2, H05RN-F orH07RH-FField supply(220-240V~, Output)N L1N L2* Connection of 2 wires 2-way valveIn case of normal closed typeIn case of normal open typeNormalclosed type- When it closes-When it opensFloorHeatingFloorHeatingFloorHeatingFloorHeatingMixingTankMixingTankMixing TankMixing Tank2Way Valve2Way Valve-When it opens- When it closesNormalOpen typeB12 : Live (L)B13 : 2WAY2 (L1)B14 : 2WAY2 (L2)B11 : Neutral (N)B10 : 2WAY1 (L2)B9 : 2WAY1 (L1)2-way motorized valvef When outlet water temperature reach to lower than 16 °C incooling mode, UFH loops will be closed.f 220-240V~f 2 wires(Normal Open or Normal Close)1. Before the installation, control kit should be turned off.2. Using the appropriate equipment to correct position of terminalblock as shown on the diagram.3. Make sure what type is you use.- Normal OPEN or Normal CLOSED.• There are 2 types of 2-way valve, normal open type andnormal closed type. Make sure to connect terminalsto right positions of terminal block. As detailed on thewiring diagram and illustrations above.CAUTION24