Troubleshooting44 Samsung Electronics4-3-4 : Error due to abnormal data of DHW tank thermistor value• DHW tank thermistor has a defective OPEN/SHORT• Refer to how to determine belowWired remocon displayCriteriaCause of problemOutdoor unit display x x x (x x x : The address of the error occurred indoor unit)NoRe-start after put the connetor in the PBA.Yes1. How to checkAfter putting out the thermistorfrom the PBA Measure its resistancevalue B/W two terminal.The thermistor needs to be replaced.NoIs the resistance valueDeviated from the temp. table,significantly?YesRe-start after replacing PBA.Temperature(°C)Resistance(KΩ)706050403020100435982115166242362553Does water tankthermistor connector come outof the PBA?Ex) In case of 26°C – its resistance : around 195KΩ