Safety 1st TH104 User Manual
Basics of Your ThermometerNormal Body TemperatureTroubleshootingnormal foreheadtemp rangeTemperature readings are different from person to person and also vary dependingupon the body location from which the temperature is measured. Foreheadtemperatures tend to be comparable to oral temperatures and approximately 1˚ lowerthan rectal temperatures for the same individual. Temperature readings are affectedby many factors including exercise, drinking hot or cold beverages prior to taking areading as well as technique.“Normal” temperature refers to each individual’s average temperature while healthy.You may want to measure and record your child’s temperature a few times when heor she is well, so that you will know what is normal for your own child. On average,temperature ranges are as follows:TEMPERATUREMETHODForeheadNORMALTEMPERATURE97°F to 99.5°FFEVERRANGE99.6°F +Display Meaning Recommended Action Display Recommended Action• Error 3, the ambient temperature is not within range• Error 5-9, the system is not functioning properly• Forehead Mode: Temperature taken is higher than 108°F (+42.2°C)• Liquid Mode: Temperature taken is higher than 176°F (+80°C)• Forehead Mode: Temperature taken is lower than 89.6°F (+32°C)• Liquid Mode: Temperature taken is lower than -7.6°F (–22°C)• Device cannot be powered on to the ready stage• Allow the thermometer to rest in a room for at least 15 minutes at room temperature.• Remove batteries, wait 1 minute and repower unit. If the message reappears, contact ConsumerCare.• Allow the thermometer to rest in a room for at least 15 minutes at room temperature.• Target is too cold to read using this thermometer. If in forehead mode, try moving unit closer tothe forehead.• Remove batteries, wait 1 minute, and repower unit. If the message reappears, contact ConsumerCare.NOTE: Room temperature is between 50°F and 104°F (10°C - 40°C).• Batteries are low. Replace them. (See Battery Information section).Press and release the ON/MEMORY button. Thermometer runs a brief self-check, then beeps and displays the ready screen. The unit will default to FOREHEADMODE. POSITION LIGHTS at front of unit come on automatically. Prep the forehead by making sure it is clear of hair and sweat. If child has recently been in a verywarm or very cold environment, wait a few minutes for their skin to adjust to room temperature before taking their temp.Once unit is positioned, press and hold the READ TRIGGER button on the rear of the thermometer for about 1 second or until the screen lights up, displaystemperature reading, and beeps (if not in mute mode.)The unit gives one long beep when temp is in normal range. Thermometer gives additional beeps and the fever bar lights up when elevated temp is detected.NOTE: High, prolonged fever requires medical attention, especially for young children. Please contact your physician. Fever chart included.After a reading is complete, the WAIT icon will flash for 5 seconds. After those 5 seconds are complete, the unit will return to READY mode. Thermometer beepsand shuts off automatically after about 30 seconds in READY mode.This thermometer can also be used to take no-touch temperatures of liquids like bath water and milk/formula. Unit defaults into FOREHEAD MODE every timeyou turn it on. To switch to LIQUID MODE, simply press the MODE button on the handle of the thermometer. NOTE: To return to FOREHEAD MODE, press MODEbutton again. NOTE: Once in LIQUID MODE, positioning lights and fever bar are no longer needed.How to Measure TemperatureSwitch Between Fahrenheit & CelsiusTechnical SpecificationsHow to Install/Replace the Batteries1 If unit is not off already, hold the POWER/MEMORYbutton for 6 seconds. Release when you see theword “OFF” appear on the screen.2 While unit is still off, hold down READ TRIGGERbutton and then POWER/MEMORY button. Holdboth down for about 5 seconds.3 After about 5 seconds, unit will power on in thenew mode.NOTE: Switching between F/C clears the memory on the unit.This thermometer comes with the batteries outside of the unit. If this is yourfirst time using this unit, start with step 1 below.Low Battery Warning:• When the icon appears on the display screen whenpowering up and using the thermometer, the batteries are lowbut may still work for a very short time.• When the icon appears and flashes by itself on the screenthe batteries are exhausted and need to be replaced.To Install Batteries:1 Use a Phillips head screwdriver to loosen battery cover screw.Remove cover.2 Remove old batteries3 Insert two AAA (or equivalent) batteries,correctly positioned with positive “+” andnegative “-” as shown in illustration.4 Place the battery cover on thethermometer and tighten thescrew to secure it in place.• This is NOT an ear thermometer. Take temperature measurements from the center offorehead. • Use caution when taking temperature readings of bath water and liquids. This product is not intended to touchthe person or item whose temperature is being measured. • ALWAYS supervise your child when using the thermometer.NEVER allow your child to use it alone.• NEVER allow children to play with this thermometer. It is not a toy. This is a sensitive electronic device and may be damagedif not used properly under parental supervision. • DO NOT expose the thermometer to extreme temperatures, humidity, directsunlight or shock, and/or dust. • Keep battery out of child’s reach. Swallowing a battery could be fatal. Battery should not becharged or placed into extreme heat as they may explode. • Used batteries should be disposed of properly.Other Battery Information: We recommend alkaline batteries for longer battery life. DO NOT mix old and new batteries.DO NOT mix alkaline, standard (carbon zinc) or rechargeable (nickel-cadmium) batteries. Non-rechargeable batteries are notto be recharged. Rechargeable batteries are to be removed from the unit before being charged. Rechargeable batteries are onlyto be charged under adult supervision. Only batteries of the same or equivalent type as recommended are to be used. Batteriesare to be inserted with the correct polarity. The supply terminals are not to be short-circuited. Check that all contact surfaces areclean and bright before installing batteries. DO NOT disassemble for any reason other than inserting or replacing batteries.Make sure the thermometer has been at room temperature for 30 minutes before use.Please be sure to read all warnings, instructions andnotations before using this product. Please keep theseinstructions as they contain important information.Forehead ModeMute Liquid ModeLow BatteryMemoryUnit of Measure (F/C)LCD DisplayON/MEASUREButton withAuto Shut-OffMode ButtonTemperatureSensor LensWARNINGUser’s Guide TH104AAA Batteries (2) ScrewBattery CoverPrecise Position Forehead ThermometerOne (1) Year Limited WarrantyDorel Juvenile Group, Inc. warrants to the original purchaser that this product(Thermometer), is free from material and workmanship defects when used under normalconditions for a period of one (1) year from the date of purchase. Should the product containdefects in material or workmanship Dorel Juvenile Group, Inc., will repair or replace theproduct, at our option, free of charge. Purchaser will be responsible for all costs associatedwith packaging and shipping the product to Dorel Juvenile Group Consumer RelationsDepartment at the address noted on the front of this document and all other freight orinsurance costs associated with the return. Dorel Juvenile Group will bear the cost ofshipping the repaired or replaced product to the purchaser. Product should be returned in itsoriginal package accompanied by a proof of purchase, either a sales receipt or other proofthat the product is within the warranty period. This warranty is void if the owner repairs ormodifies the product or the product has been damaged as a result of misuse.This warranty excludes any liability other than that expressly stated previously, including butnot limited to, any incidental or inconsequential damages.SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL ORCONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOTAPPLY TO YOU.THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVEOTHER RIGHTS THAT MAY VARY FROM STATE TO STATE.Measurement Temperature Range:Forehead Mode: 89.6°F to 108.0°F (32°C to 42.2°C)Liquid Mode: -7.6°F to 176.0°F (-22°C to 80°C)Measurement Accuracy:Forehead Mode: +/- 0.4°F (0.2°C) within 95°F to 107.6°F (35 to 42°C)+/- 0.5°F (0.3°C) For other rangeLiquid Mode: +/- 0.5°F (0.3°C) within 71.6°F to 108°F (22 to 42.2°C)others +/- 0.4% or +/- 0.4°F (0.2°C) whichever is greater.Operation Environment: 50°F to 104.0°F (10 to 40°C)Humidity up to 85% (non condensing)Storage Environment: -4°F to 122°F (-20 to +50°C)Humidity up to 85% (non condensing)Care and MaintenanceCleaning Temperature Sensor Lens:• Clean very gently with a soft, alcohol-moistened cloth.• Do not use an excessive amount of alcohol.• Do not pour alcohol directly on sensor.Cleaning Thermometer Body:• Use a soft, dry cloth to clean thermometer body.Notes:• DO remove battery if stored for a long period of time.• DO store thermometer in a dry place at room temperature.• DO take special care not to scratch the sensor or display window.• DO NOT use abrasive cleaning agents, thinners or benzene for cleaning.• DO NOT expose thermometer to extreme temperatures, humidity or direct sunlight.• DO NOT drop thermometer.• DO NOT submerge any part of the product in water.Position LightsRead TriggerFever Light• For best accuracy, wait one minute between temperature measurements so that thermometer has time tore-acclimate to the room’s temperature.• Do not return this product to the place of purchase. If any parts are missing, email support@djgusa.zendesk.com, or chat with us at www.safety1st.com. You can also call Consumer Care at (800) 544-1108.Have ready the model number (TH104) and date code (manufacture date located on package).• Install new batteries and re-try function before calling Consumer Care on electronics.1. Turn Thermometer On and Prep Forehead2. Position Thermometer3. Measure Temperature4. Fever Reading Indicator5. Wait timer &Auto Shut-Off6. Liquid ModeThe POSITION LIGHTS are LED lights and are meant to help you feel confident about how you are aiming and distancing the unit.-AIMING: The SENSOR LENS points at the area of the forehead between the two red POSITION LIGHTS. The right spot to aim the SENSOR LENS isat the base of the forehead, just above the eyebrows. So, when properly positioned, the LOWER POSITION LIGHT should be between the eyebrows.-DISTANCE: For accurate temperatures, the unit should be within 1.5 inches (4 cm) of the forehead. When the unit is 1.5 inches from the forehead,the UPPER POSITIONING LIGHT will be directly above the LOWER POSITIONING LIGHT (vertically.) When closer or farther away, the lights moveaway from each other in opposite directions.Hint: If a child is uncomfortable seeing the thermometer coming toward his face, try turning the thermometer upside-down.The POSITIONING LIGHTS work the same when the thermometer is upside down.MemoryWhile unit is ON, press the ON/MEM button. The number “1” will appear with the“ ” icon to indicate this is the first reading in the memory.Release the ON/MEM button to see the reading. Press theON/MEM button again to toggle through up to 25 records.Mute FunctionTo set to mute: While unit is ON, press the ON/MEM button for 3 seconds until you seethe “ ” icon appear. Then release ON/MEM button.©2019 Dorel Juvenile Group, Inc. Safety 1st™ and the Safety 1st logo anddesign are trademarks of Dorel Juvenile Group, Inc. Safety 1st™ y el logotipode Safety 1st y su diseño son marcas comerciales de Dorel Juvenile Group, Inc.(800) 544-1108 www.safety1st.com. Styles and colors may vary. Los estilosy los colores pueden variar. Made in CHINA. Hecho en CHINA. Distributed by(distribuido por) Dorel Juvenile Group, Inc., 2525 State St., Columbus, IN 47201-7494. Dorel Juvenile Canada, 2855 Argentia Road, Unit 4, Mississauga, ON L5N8G6. Importado y Distribuido en Chile por: Comercial e Industrial Silfa S.A. - SanIgnacio 0201 / Parque Industrial Portezuelo Quilicura, Santiago Chile. Fono (562)2339 9000. En Perú por: Comexa S.A. - Los Libertadores 455 – San Isidro, Lima –Perú. Fono (511) 4469014. En Centro América, Caribe y Ecuador por: Best BrandsGroup S.A. – Av. Balboa, Bay Mall Plaza, Planta Baja, local 9, Panamá. - Fono:(507) 300 2884. En Colombia por: Baby Universe S.A.S. - Vía 40 No. 77-29,Barranquilla, Colombia - Fono: (575) 353 1110 Importador: DJGM, S.A. DE C.V.Gabriel Mancera No. 1041 Col. Del Valle, Benito Juárez C.P. 03100 México, Ciudadde México R.F.C. DJG140305GN9 Tel. (55) 67199202 04/22/19 4358-7665BPLEASE NOTE:The sensorlens is themost delicate partof the thermometer.To ensure accuratereadings it must beclean and intact. |
Related manuals for Safety 1st TH104
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved