HZ42E Regency Horizon™ Gas Fireplace 5SAFETY LABELThis is a copy of the label that accompanies each HZ42E-NG and HZ42E-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here foryour review.NOTE: Regency ® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.COPY OF SAFETY DECALFor the State of Massachusetts, installationand repair must be done by a plumber orgasfitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, flexible con-nectors shall not exceed 36 inches in length.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE371DOOR SEAL: Pleasecheck that the door isproperly sealedFPI Fireplace Products International Ltd. Delta, BC, CanadaMinimum Clearances to Combustibles /Degagement Minimum De Materiaux CombustiblesSerial No./ No de serie918-931MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.Listed:Certified for/Certifi e pour:Tested to:VENTED GAS FIREPLACE HEATER /CANADA and U.S.A.FOYER AU GAZ À ÉVACUATIONéCAN/CGA-2.17-M91,ANSI Z21.88a-2007/CSA 2.33a-20074001172Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE. Made in Canada/ Fabrique au Canada(See Instruction Manual fordetailed instructions)É ÉéQUIP A L'UISINE POUR GAZ PROPANECONCU POUR ETRE POELE: Mod le HZ42EPROPANE GAS: Model HZ42E-LPMinimum supply pressureManifold pressure highManifold pressure lowOrifice sizeMinimum inputMaximum inputAltitudeNATURAL GAS: Model HZ42E-NGAPPAREIL FONCTIONNANT AU NATURAL GASCONCU POUR ETRE POELE: Mod le HZ42EPression d'allimentation minimumPression à la tubulure d' chappement lev ePression à la tubulure d' chappement basseGrandeur de l'injecteurD bit minimum selonD bit maximum selonl'altitudeCalorifiqueCalorifiqueéé é éééé5.0" (1.25kPa)3.5" (0.87kPa)1.6" (0.40kPa)#40 DMS0-4500 ft/pi (0-1372 m)WC/C.E.WC/C.E.WC/C.E.17,500 Btu/h (5.13 kW)26,000 Btu/h (7.62 kW)Pression d'allimentation minimumPression à la tubulure d' chappement lev ePression à la tubulure d' chappement basseGrandeur de l'injecteurD bit minimum selonD bit maximum selonl'altitudeCalorifiqueCalorifiqueé é éééé12“ WC (2.98 kpa)WC/C.E.WC/C.E.19,500 Btu/h (5.71 kW)24,500 Btu/h (7.18 kW)10" (2..49kPa)6.4" (1.60kPa)#53 DMS0-4500 ft/pi (0-1372 m)Minimum supply pressureManifold pressure highManifold pressure lowOrifice sizeMinimum inputMaximum inputAltitudeDEFABCSide WallsA 8” (203mm)B 22” (559mm)C 13" (330mm)D 13” (330mm)E 84" (2133mm)F 36" (914mm)CeilingMin. Mantel HeightMax. Mantel DepthAlcove WidthAlcove DepthThis appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, inthe United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational VehiclesThis appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. Seeowner's manual for details.Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and SafetyStandard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for RecreationalVehicles.This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLYCet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure siles règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL