Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- related documentation
- Tips, Notes, Cautions and Warnings
- Overview
- specifications
- standard features
- Command Centers
- EMI & Lightning Transient Protection
- Listings and Approvals
- Installation
- installing the assembly
- finishing the installation
- testing the system
- Power Supply
- Replacing the Battery
- Battery Supervision
- Battery Discharge/Recharge Schedule
- Power Outputs
- Optional Relays Required
- Terminal 8
- Telephone Connections
- communication failure
- Ground Start
- Watchdog Feature
- On-board Points
- Wiring Information for Installations using the Ademco AB-12 Bell/Housing
- Off-board Points
- Figure 14a: Connecting the D8125 POPEX to the D9412G Panel
- Figure 14b: Connecting the D8125 POPEX to the D7412G Panel
- Installing the D8125 POPEX Module
- Wiring Data Expansion Loops to POPEX Modules
- D8128D OctoPOPIT Module
- Installing the OctoPOPIT
- OctoPOPIT Sensor Loops
- Figure 16a: Connecting D8128D OctoPOPITs to the D9412G
- Figure 16b: Connecting D8128D OctoPOPITs to the D7412G
- Off-board Relays
- Figure 17b: D8129 Connections to the D7412G
- D811 Arm Status Relay Module
- Figure 18b: D811 Module Wiring to the D7412G
- Arming Devices
- D268/D269 Independent Zone Control, D279A Independent Zone Control
- Keyswitch
- SDI Devices
- Switch Settings
- SDI Address 88
- Programmer and Accessory Connections
- Faceplates
- D7412G Faceplate
- Appendix A: System Wiring Diagrams, Issue A
- A.2 D9412G Control/Communicator, 2 of 3
- A.3 D9412G Control/Communicator, 3 of 3
- A.4 D7412G Control/Communicator, 1 of 3
- A.5 D7412G Control/Communicator, 2 of 3
- Figure 25c: D7412G System Wiring Diagram, 3 of 3
- Appendix B: Point Address Charts
- B.2 ZONEX 2, Points 129 to 247 (D9412G Only)
|
D9412G/D7412G Operation & Installation Guide43488D Page 50 © 2002 RadionicsD9412G/D7412GOff-board RelaysThe number of D8129 OctoRelays that can be connected to each Zonex terminal on the D9412G panels is limitedby the number of D8128D OctoPOPITs connected.Using D8129 OctoRelays and D8128D OctoPOPITs together on the same Zonex Terminals is limited anddepends on the number of D8128D OctoPOPITs and D8129 OctoRelays connected to a single Zonex Bus.Refer to Table 11for information on the maximum number of D8128Ds and D8129s that may be connectedto a single Zonex Bus.Table 11: Number of D8128Ds used with D8129sFigure 17b: D8129 Connections to the D7412GFigure 17a: D8129 Connections to the D9412GGR NR e se t PinDis a b le A ll E xc e pt Ba tte ryCha rg in g An d Prog r am m in gPERIPHERAL DEVICE CONNECTIO NSRED POW ER +YELLOW DATA BUS AGREEN DATA BUS BBLACK COMM ONZONEX OUT 1ZONEX IN1N.F.P.A.Style 3 .5Sign a lingLineCircuits323130292827PROGCONNPoint 8G ND FA ULTD e te ctENABLEDISABLEZONEX OUT 2 2625ZONEX IN2ZONEX POW ER + 24ZONEX COMM ON 2321 22On-B oard Poi nts1 2 3 4 5 6 7 8GN DAU XDATA D 812 9 OC TO REL AYS FO R REL AYNU MBER S 6 5 TO 128 . CO NN ECTO CTOR ELAYS IN PAR ALLEL .1 2 3 4 5 6 7 8GN DAUXD ATA D8 129 O CTO RELAYS FO R RELAYNU MBER S 1 TO 6 4. C ON NECTO CTO REL AYS IN PAR ALLEL .1 2 3 4 5 6 7 8GNDAUXD ATA D8 129 O CT OR ELAYS FO R RELAYNUMBER S 1 T O 6 4. C ON NECTOC TO REL AYS IN PARAL LEL.EARTH GR OCOM MONBAT TERY NM ax imum Cha rgingCurre nt1 .4 Am ps.BAT TERY POSITIVE ONLYREL AY AREL AY BREL AY C+ AUX PO12345678910CLASS 2 TRANS16 .5 VAC4 0 VACPart No. D1 640Intern ally FuseRequires UnswDo Not Sha reLow Ba tteryRE DPRALReGROU ND FAULPinBa tte ryam mingE CONNECTIONSPOWER +DATABUS ADATABUS BCOMMONZONEX OUT 1ZONEX IN 1323130292827PROGCONNIf the # of D8128Dsconnected to a singleZONEX bus is:Then do not connectmore than this # ofD8129s:9 610 511 412 313 114 1
PreviousNext |