QLT PBX D Series Installation Manual
Areas of applicationThe device may only:• be used for the specified applications.• be used for safe installation in dry and clean environment.• be installed in such a way that access is only possibleRespect rated values on labelusing a toolDimensions (mm)ENQualitron s.r.l. Via Dolomiti 15 20027 Rescaldina ( Milano ) Italy WWW.QLT.IT qlt@qlt.itQLT RInstallation GuidePower factorMax. main currentStandby powerInput2Input1Technical DataPush line Max cable lenghtOperating frequenciesMax output current 48VMax output powerMax output current 24VMin Output loadProtectionsSurge capabilityEfficiency full-loadRated supply voltageOutputInput selectorOperating temperatureStorage temperatureDimensions LxPxAProtection degreeConnectionsTC pointInsulationWeightKeep this document carefullyRespect the safety and accident prevention regulationsDispose of according to instructionsDIP-SWITCHES settings with the device turned offSwitch off the mains supply before device connectionInstallation of this device may only be carried out byspecialist staff .Safety notePno Psb Pnet LoadAlways ON0,5W 0,5W 0,5WInstallation guide - Rev 328_13Area d’applicazioneIl dispositivo può solo essere:• usato per le applicazioni specificate.• usato per l’installazione sicura in un ambienteasciutto e pulito.• essere installato in modo tale che l’accesso sia possibileRispettare sempre i dati di targasolo usando un utensile.ITProcedura di sincronizzazioneIn impianti con più alimentatori controllati a pulsante, lasincronizzazione si ottiene effettuando una pressione prolungata sulcomando fino al raggiungimento del livello massimo di luce su tutti idispositiviIn case of systems with more devices controlled by push-button, synchronization is achieved by holding the control for along time until maximum light is reached on all devices.Synchro procedureFunzionamento a pulsanteMemoria di stato anche in assenza di tensione di reteMemoria di stato Push button operationState memory even in absence of mains voltageState memoryNota sulla sicurezzaInstallazione consentita solo con personale specializzatoRispettare le norme sulla sicurezza e prevenzioneinfortuniTogliere alimentazione prima del collegamentoImpostare i DIP-SWITCHES ad apparecchio spentoConservare con cura il presente documentoSmaltire secondo indicazioni sopra riportateGuida di InstallazioneQuesto documentoThis documentL’apparecchioThe DeviceScatola singolaInner PackageIngresso di comando 2Corrente massimaPotenza assorbita a riposoLunghezza cavi pulsanteMax corrente di uscita 48VFattore di potenzaTensione di uscitaMax potenza di uscitaIngresso di comando 1Max corrente di uscita 24VMinima potenza uscitaEfficienza carico maxTensione di alimentazioneSelezione degli ingressiFrequenza operativaProtezioniDati tecniciPesoTemperatura magazzinoTemperatura operativaSovratensione di reteTC punto di controlloConnessioniIsolamentoGrado di protezioneDimensioni LxPxA75W, 100W, 150W, 200W10WSovratemperatura-10°C ... +40°CCarico aperto, Corto circuito, Sovraccarico24-48V+-5%Classe II SELV 3750V PRI-SEC0,9870°(75W), 75°(100W), 77°(150W),80°(200W)-15°C ... +50°C210x75x35 mm335..360g250Hz PWM20m con 0.5 – 2.5mmqIP 20<0,5WDIP-Switch1,6A - 2,08A - 3,12A - 4,16A>1KV L-NMorsetti rapidi e a vite 0.5..2.5mmq110-240V AC>91..93%0,7..1,12ADALI / Pulsante ON/OFF/Dimmer0_10V e 1_10V o potenziometro 47K3,12A - 4,16A - 6,25A - 8,33A1,6A - 2,08A - 3,12A - 4,16A>1KV L-N<0,5W75W, 100W,150W, 200WDIP-Switch-10°C ... +40°C-15°C ... +50°COvertemperature24-48V+-5%3,12A - 4,16A - 6,25A - 8,33ADALI / Push button ON/OFF/Dimmer210x75x35 mm0,98>91..93%20m con 0.5 – 2.5mmq10W110-240V ACOpen load , short circuit, OverloadFast and screw connectors 0.5..2.5mmq250Hz PWMClassII SELV 3750V PRI-SEC70°(75W), 75°(100W), 77°(150W),80°(200W)0,7..1.12A0_10V e 1_10V or poti 47KIP 20335..360gwww.qlt.itPotenze: 75W, 100W, 150W, 200W - RegolabiliAlimentatori serie PBXxxD 24..48V Power: 75W, 100W, 150W, 200W - DimmablePower supply PBXxxD 24..48V2009/125/ECODESIGN regulation (EU) n°2019/2020 and 341/2021amendment EN 61347-2-13:2014 + A1:2017;Direttive e norme UEEN 55015:2019 + A11:2020; EN 61000-3-3:2013; EN 61457:2009;EN IEC 61000-3-2:2019 + A1:2021EN 63000:20182014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU +2015/863/EU (RoHs);EN 61347-1:2015 + A1 :2021 , EN IEC 62384:2020IEC 62386-102:2014 + AMD1:2018; IEC 62386-207:2018EN IEC 62442-3:2022UE Standards and Directives2014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU + 2015/863/EU(RoHs);IEC 62386-102:2014 + AMD1:2018; IEC 62386-207:2018EN 61347-1:2015+ A1 :2021 , EN IEC 62384:20202009/125/ECODESIGN regulation (EU) n°2019/2020 and 341/2021amendment EN 61347-2-13:2014 + A1:2017;EN 55015:2019 + A11:2020; EN 61000-3-3:2013; EN 61457:2009;EN IEC 61000-3-2:2019 + A1:2021 EN 63000:2018 EN IEC 62442-3:2022Connections0.5–2.5 2mm / 13–20 AWG4..7 mmsolid/fine-strandeda filo unico/a fili sottiliM M110SELVLAP |
Related manuals for QLT PBX D Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved