SINGLE PHASE POWER METERIsolated V/I converter -RS485 Modbus - Datalogger QA-POWER-MSINGLE PHASE POWER METERIsolated V/I converter -RS485 Modbus - DataloggerSingle-phase power meter RMS, and Voltage/Current Isolated. SignalConverter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequencymeasurement. Configurable via USB, DIN rail mounting, 4 kV galvanicisolation, universal supply AC/DC. Configurable alarm contact, RS485Modbus and Analog output. DATALOGGING via USB with pen drivestick memory and download storage data on excel importable files. RTCReal Time Clock integrated.INPUTVOLTAGE: Up to 1000 V DC / 600 V AC fully configurable via USB.CURRENT: Up to 10 A AC/DC direct (more by using external CT).1 01 2016APPLICATIONPhotovoltaic: parallel string voltage monitoring.Energy Management: direct communication via RS485 Modbus toall Master Modbus devices.High Voltage AC/DC converter.High Current AC/DC converter using external CT.Local and Remote monitoring at the same time.OUTPUTCURRENT: 0...20 mA programmable, max load 600 ohm.VOLTAGE: 0...10 V programmable, min load resistence 2 kohm.RS485 MODBUS: bus connection on the basis of the module orterminal, dip-switch for setting address and baudrate.CONTACT OUTPUT: Optomos contact, programmable NO alarmcontact by free interface software FACILE QA-POWER, retransmissionor storage.QA-POWER-MPen Drive USB Datalogger !POWER SUPPLY 10..40 Vdc, 20-28 Vac, 50-60 HzABSORPTION Maximum 2.5 VAPROTECTION INDEX IP20ACCURACYWORKING FREQUENCY DC or 1...400 HzTEMPERATURE COEFFICIENT < 200 ppm/°CWORKING TEMPERATURE -15...+65°CSTORAGE TEMPERATURE -40°C... +85°CISOLATION 4 kV input, 1.5 kV between output,RS485 and power supply.HUMIDITYALTITUDEterminals, RS485 bus and Supply connection ready on thebase of module (connector not included, on request).CONNECTIONS Removable terminals 5.08 mmCE STANDARDSEN61000-6-4/2006 + A1 2011;EN64000-6-2/2005;EN61010-1/2010.DIMENSIONS 17.5 x 100 x 112 mm (terminal excluded)DATA LOGGERNon-volatile memory. Log on USB OnTheGo port by PenDrive stick memory. RTC Real Time Clock integrated allowsyou to manage the log with date and time.CONFIGURATIONBy free software FACILE QA-POWER-M to configure all ofthe conversion parameters like span, zero, alarm contactand log via USB port or via RS485. Dip-switch for settingmodbus address and baudrate.MOUNTING DIN rail mounting with removableUp to 2000 m s.l.m.10...90% not condensingMEASURE0,5% F.S.Irms, Vrms, Watt, Var, Va, Vpk, Ipk, Frequency,Cosφ, Energy bidirectional, THDENGLISH