UNPACKING & INSPECTIONStorage4UNPACKING & INSPECTIONStorage• Dry the pump thoroughly before storing.• Store the pump in a cool, dry location free from dirt and vibrations.• Limit the pump's exposure to humidity.• If storing long-term, ensure that the cable entry is secure, the impeller is rotated every 2 months to pre-vent the seals from sticking, and that the oil chamber is filled with clean oil prior to use.Unpacking1. Check for missing and damaged parts. Immediately report any issues to the transport company andequipment manufacturer.2. Examine the pump upon arrival for shipping damage.• If there is damage, notify the shipping agent and your sales representative.Lifting1. Use the eye-bolts on the model to lift.Risk of severe injury or death.• Improper handling of the equipment may result in bodily injury or property damage.• When lifting the pump, securely fasten it using equipment rated to handle the pump's weight using the lifting handle.• Never lift the pump by its cable.Risk of damage to equipment.• Ensure that the pump is securely fastened in a horizontal position for transportation so that it does not roll or fall over.• If the pump package is dropped, impacted, or otherwise mishandled, malfunction can occur.Risk of personal injury or damage to pump or other equipment.• Use suitable lifting equipment, in good condition, rated for at least 5 times the weight of the pump.11High Head Configuration High Volume Configuration