Location selectionInstallation 732. Location selection2.1 Indoor unit location selection The place shall easily support the indoor unit’s weight. The place can ensure the indoor unit installation and inspection. The place can ensure the indoor unit horizontally installed. The place shall allow easy water drainage. The place shall easily connect with the outdoor unit. The place where air circulation in the room should be good. There should not be any heat source or steam near the unit. There should not be any oil gas near the unit There should not be any corrosive gas near the unit There should not be any salty air neat the unit There should not be strong electromagnetic wave near the unit There should not be inflammable materials or gas near the unit There should not be strong voltage vibration.2.2 Outdoor unit location selection The place shall easily support the outdoor unit’s weight. Locate the outdoor unit as close to indoor unit as possible The piping length and height drop cannot exceed the allowable value. The place where the noise, vibration and outlet air do not disturb the neighbors. There is enough room for installation and maintenance. The air outlet and the air inlet are not impeded, and not face the strong wind. It is easy to install the connecting pipes and cables. There is no danger of fire due to leakage of inflammable gas. It should be a dry and well ventilation place The support should be flat and horizontal Do not install the outdoor unit in a dirty or severely polluted place, so as to avoid blockage of the heatexchanger in the outdoor unit. If is built over the unit to prevent direct sunlight, rain exposure, direct strong wend, snow and other scrapsaccumulation, make sure that heat radiation from the condenser is not restricted.More than 60cm(23.62in)More than 200cm(78.74in)More than 30cm(11.81in)More than 60cm(23.62in)(Service space︶Fence orobstaclesMore than 30cm(11.81in)