Fig. 66.5. DEFLECTION (16:9 MODE) ADJUSTMENT / CONFIRMATION6.5.1. DATA SETTING (16:9)1. Copy the adjusted data of 100i / 4:3 mode to 100i / 16:9 in the table 1 (Except H-POS, V-S-Correct).2. Copy the adjusted data of 120i / 4:3 mode to 120i / 16:9 in the table 1 (Except H-POS, V-S-Correct).3. Copy the adjusted data of 50p / 4:3 mode to 50p / 16:9 in the table 1 (Except H-POS, H-AMP, V-S-Correct, C-Correct) and copythe data of 100i / 4:3 to 50p / 16:9 about H-AMP and C-Correct.4. Copy the adjusted data of 60p / 4:3 mode to 60p / 16:9 in the table 1 (Except H-POS, H-AMP, V-S-Correct, C-Correct) and copythe data of 120i / 4:3 to 60p / 16:9 about H-AMP and C-Correct.6.5.2. V-AMP (16:9) ADJUSTMENT1. Receive PAL monoscope pattern.2. Set the aspect to 16:93. Set scan mode to 100 Hz4. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (100i / 16:9).5. Set scan mode to progressive.6. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (50p / 16:9).7. Receive NTSC monoscope pattern.8. Set scan mode to 100 Hz.9. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (120i / 16:9).10. Set scan mode to progressive.11. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (60p / 16:9).Fig. 76.6. 525p DEFLECTION ADJUSTMENT / CONFIRMATION6.6.1. V, H-HOLD CONFIRMATION1. Receive 525p signal through Yuv input.2. Confirm V, H-hold is normal.21TX-29P180X