6.13. Remove the stand bracketsand rear mounting metals1. Remove the plasma panel section from the servicing standand lay on a flat surface such as a table (covered) with theplasma panel surface facing downward.2. Remove the stand brackets (left, right) fastening screw (×2each).3. Remove the rear mounting metals (left, right) fasteningscrews (×4 each).4. Remove the stand brackets and rear mounting metals.5. Remove the fastening screws (×4 each).6. Remove the stand brackets from rear mounting metals.6.14. Remove the C1-Board1. Remove the tuner unit. (See section 6.4.)2. Remove the stand bracket (right) and the rear moutingmetal (right). (See section 6.13.)3. Remove the flexible cables holder fastening screws (×8).4. Disconnect the flexible cables (CB1, CB2, CB3, and CB4).5. Disconnect the flexible cables (C10 and C11).6. Remove the screws (×6 ) and remove the C1-Board.6.15. Remove the C2-Board1. Remove the tuner unit. (See section 6.4.)2. Remove the flexible cables holder fastening screws (×8).3. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).4. Disconnect the flexible cables (C20, C21 and C22).5. Remove the screws (×6 ) and remove the C2-Board.6.16. Remove the C3-Board1. Remove the tuner unit. (See section 6.4.)2. Remove the stand bracket (left) and the rear mouting metal(left). (See section 6.13.)3. Remove the flexible cables holder fastening screws (×6).4. Disconnect the flexible cables (CB9, CB10 and CB11).5. Disconnect the flexible cable (C32).6. Disconnect the connectors (C33 and C35).7. Remove the screws (×5 ) and remove the C3-Board.13TH-58PE75U