Adjustment MethodRGB white balance adjustmentInstrument Name Connect to Remarks INTERNAL PATTERN – 100% WHITE Color analyzer( Minolta CA-210 or equivalent )Panel surfacePicture menu: STANDARDUser setting: Normalexcept PICTURE: max 30Procedure Remarks[Conditions] Make sure the front panel to be used on the final set is fitted. Center position[Adjustment]1. Set COMPONENT / RGB-IN SELECT to COMPONENT2. Select the IIC mode “LCD Drive Adj.” item.3. Check that the color temperature is “MID”4. Output a white balance pattern.5. Touch the signal receiver of color analyzer to the highlight window’s center.6. Fix G drive at 30h and adjust B drive and R drive so x, y become the “Colourtemperature NORMAL(Mid) in the below table.7. At least fix one of the RGB’s drive data at 30h and adjust the others drive so x/y(The highest RGB’s drive value is 30h)Table W/B adjustment valuesColor Temperature x yNORMAL(Mid) 0.288 0.296Adjustment targetHi-light. X ± 0.005 y ± 0.005Hi-light is target of the number at drive adjustment in the hi–light windows.Therefore, it is not target of the hi-light number at after adjustment white balance.Note :Internal signal: STANDARDAspect: FullPicture setting: StandardBacklight: 100(Default) “7“ key: color temperature selectColor temperature – Normal(Mid.)Let the panel stand for more than 3hours at more than 20 C.Basically perform adjustment in theambient environment of roomtemperature more than 20 C.The aging time is more than20 minat above room temperature.Change DRIVE(R,G,B) by UP/DOWN buttons on the remote control+-Change Value Register by VOL+/- buttons on the remote control