New Technical Features2 new technical features have been added to the 2011 models to assist the service technicians speed up therepair process. The ability of the power LED to match the number of blinks of the first and last SOS blinking codesdetected by the TV as listed on the “SELF Check” menu. The delaying of the power LED blinking reaction by 10 seconds when the SC/SN board is isolated.1st.occurrenceafter shipment3rdoccurrencebefore last2nd.occurrenceafter shipmentLastBeforelastThe power LED can be forced to duplicate the number of blinks of the first and last SOS conditions detected by the TV.This can be done while the power LED is blinking after a shutdown condition has occurred.Procedure:To duplicate the number of blinks of the last SOS detected.While the power LED is blinking, press the “VOL+” on the remote control once to make the power LED blink the samenumber of times as the last blinking code detected by the TV.To duplicated the number of blinks of the first SOS detected.Press the “VOL-” once to make the power LED match the number of blinks of the first SOS blinking code detected.This can help in determining if the symptom shown by theTV when it first failed (Most likely during operation), haschanged to another blinking code when checked by theservice technician.Press VOL+ to see thelast SOS detectedPress VOL- to see the firstSOS detectedPTCT: 0a . 0a . 0a . 0a . 06SOS History asshown on the“Self Check”menuNewSlide 7