227.15. Remove the Hanger metals andthe Stand brackets1. Remove the Plasma panel section from the servicingstand and lay on a flat surface such as a table (coveredby a soft cloth) with the Plasma panel surface facingdownward.2. Remove the Hanger metals (L, R) fastening screws (×4each) and remove the Hanger metals (L, R).3. Remove the Stand brackets (L, R) fastening screws (×4each) and remove the Stand bracket metals (L, R)and the Stand brackets (L, R).7.16. Remove the C1-Board1. Remove the Control button unit. (See section 7.8.)2. Remove the flexible cables holder fastening screws (×8).3. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).4. Disconnect the flexible cable (C10).5. Remove the screws (×4 ) and remove the C1-Board.7.17. Remove the C2-Board1. Remove the Hanger metal R and the Stand bracket R.(See section 7.15.)2. Remove the flexible cables holder fastening screws (×8).3. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).4. Disconnect the flexible cables (C20, C21 and C26).5. Disconnect the connector (C24).6. Remove the screws (×4 ) and remove the C2-Board.7.18. Remove the C3-Board1. Remove the Tuner unit. (See section 7.5.)2. Remove the Hanger metal L and the Stand bracket L.(See section 7.15.)3. Remove the flexible cables holder fastening screws (×14).4. Disconnect the flexible cables (CB9, CB10, CB11, CB12,CB13, CB14 and CB15).5. Disconnect the flexible cables (C31 and C36).6. Disconnect the connectors (C33 and C35).7. Remove the screws (×5 ) and remove the C3-Board.