238.16. Remove the Hanger metals andthe Stand brackets1. Remove the Plasma panel section from the servicingstand and lay on a flat surface such as a table (coveredby a soft cloth) with the Plasma panel surface facingdownward.2. Remove the Support metal. (See section 8.15.)3. Remove the Hanger metals (L, R) fastening screws (×6each) and remove the Hanger metals (L, R).4. Remove the Stand brackets (L, R) fastening screws (×4each) and remove the Stand bracket covers (L, R)and the Stand brackets (L, R).8.17. Remove the C1-Board1. Remove the Control button unit. (See section 8.8.)2. Remove the Hanger metal R and Stand bracket R. (Seesection 8.16.)3. Remove the flexible cables holder fastening screws (×10).4. Disconnect the flexible cables (CB1, CB2, CB3, CB4 andCB5).5. Disconnect the flexible cable (C10).6. Disconnect the connector (C14).7. Remove the screws (×5 ) and remove the C1-Board.8.18. Remove the C2-Board1. Remove the Support metal. (See section 8.15.)2. Remove the flexible cables holder fastening screws (×10).3. Disconnect the flexible cables (CB6, CB7, CB8, CB9 andCB10).4. Disconnect the flexible cables (C20, C21, C22 and C26).5. Remove the screws (×5 ) and remove the C2-Board.