237.10. Remove the Hanger metals andthe Stand brackets1. Remove the Plasma panel section from the servicingstand and lay on a flat surface such as a table (coveredby a soft cloth) with the Plasma panel surface facingdownward.2. Remove the Stand brackets (L, R) fastening screws (×3each) and the Stand brackets (L, R).3. Remove the Hanger metals (L, R) fastening screws (×2each) and remove the Hanger metals (L, R).7.11. Remove the C1-Board1. Remove the Hanger metal R and the Stand bracket R.(See section 7.10.)2. Remove the flexible cables holder fastening screws (×8).3. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).4. Disconnect the flexible cables (C10 and C11).5. Remove the screws (×3 ) and remove the C1-Board.7.12. Remove the C2-Board1. Remove the Tuner unit. (See section 7.5.)2. Remove the Hanger metal L and the Stand bracket L.(See section 7.10.)3. Remove the flexible cables holder fastening screws (×8).4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).5. Disconnect the flexible cables (C20 and C21).6. Disconnect the connectors (C23 and C25).7. Remove the screws (×3 ) and remove the C2-Board.