3. Press to close the tray.4. Press “CD DIRECT PLAY (5)” and wait until the tray is open.5. Press and remove the CD.6. Press to close the tray.7. Press “n/STOP” to indicate Error Code.· If several problem exist, error code will change each time when “n/STOP” is pressed. (e.g. F15 → F26 → F16 ....etc).12.5. To clear all Error code1. Press and hold button for 5 seconds.2. FL indicator shows “CLEAR” for 1 second and change to “T”.12.6. To exit from Self-Diagnostic function1. Press button on main unit or remote control.12.7. Power Amplifier Failure (F61)1. When power amplifier fail, F61 will indicate automatically .12.8. Description of Error Code12.8.1. Abnormality detection for Deck Mechanism blockNo. Abnormal Items Error Display Method of Detection1 MODE SW abnormal H01 Normal operation during mecha transition, MODE SW abnormal ismemorized. The content of abnormality can be confirmed in theabnormal detection mode explained in the later section.2 REC INH SW abnormal H02 The content of abnormality can be confirmed in the abnormal detectionmode explained in the later section.3 HALF SW abnormal H03 The content of abnormality can be confirmed in the abnormal detectionmode explained in the later section.4 Reel pulse abnormal F01 The content of abnormality can be confirmed in the abnormal detectionmode explained in the later section.12.8.2. Abnormality detection for CD/Changer blockNo. Abnormal Items Error Display Method of Detection1 REST SW abnormal F15 Under normal operation (Self-Diagnostic Mode inclusive), this erroroccurs when the REST SW ON is not detected within the specified timeand shall be memorized.2 Transmission error between CD servoLSI and miconF26 Under normal operation (Self-Diagnostic Mode inclusive), this error occurswhen the selection is set to CD and SENSE=’H’ is detected andSENSE=’L’ is not detected within a fail safe time (20ms) after systemcommand transmission was sent.3 CLAMP SW abnormal F16 Refer to section 12.8.4 (Mechanism Error Code Table) [M-0A] error isdetected.4 BOTTOM SW abnormal F17 Refer to section 12.8.4 (Mechanism Error Code Table) [M-09] error isdetected.5 POSITION SW abnormal F27 Refer to section 12.8.4 (Mechanism Error Code Table) [M-05 ~ M-08] erroris detected.6 SW1 abnormal F28 Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] erroris detected.7 SW2 abnormal F29 Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] erroris detected.8 OPEN SW abnormal H15 Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error isdetected.9 CLOSE SW abnormal H16 Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error isdetected.10 DISC SENSOR F30 Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error isdetected.44SA-AK23 0GCP