6. Refer to wiring diagram (Page.5)Follow all the local electrical safety codes. As well asthe National Electrical Code (NEC).Using UL approved wire nuts, connect house powerwires to ventilating fan wires (Fig.6):Black to black; white to white; green to green.Make sure all connections are fastened firmly afterwiring is finished.Replace the junction box plate, and then replacelighting cord to hook. (Fig.5)Fig.10Fig.9Fig.8Fig.58. Finish ceiling work. Ceiling hole should be alignedwith the edge of the flange. (Fig.8)(Fig.10)INSTALLATION (JOIST MOUNTING- ) CONTINUED7. Install the circular duct (4 inches) to the adaptor andsecure it with duct tape or clamps. (Fig.7)Fig.7Circular ductConduitCorrectIncorrect9. Install the fluorescent lamps and then install thenight lamp. (Fig.8)Fluorescent lamp12 5/8 (319)17 3/8 (441)Screw driverFig.6Junction box plateBlack to blackWhite to whiteWhite to whiteBlack to blackBlack to blackWhite to whiteBlack to blackJunction boxGreen to greenWire nutFan bodyJoist4 Long screws (ST4.2X20)Slot Mounting springGrilleSwitchlabelsSwitchlabelsFor Model FV-11VHL2 For Model FV-11VH2Note:Do not mount grille and springs conversely. Ifthe grille is mounted in the opposite direction,the grille can not be fitted to the ceiling, sothen reverse the grille position and try tomount again.10. Insert mounting springs into slots as shown andmount grille to fan body. (Fig.9)Duct tapeor clampsScrewJunction boxplate5. Remove the lighting cord out from hook (FV-11VHL2),then remove junction box plate and secure conduit orstress relief to wiring box knock-out hole.(Fig.5)Lighting cordHookConduitNight lamp