33TEMPERATURE RECORDER (OPTION)WARNINGAlways disconnect the power supply to the unit prior to attachment of a temperature recorder inorder to prevent electric shock or injury.A temperature recorder is available for the freezer as an optional component. The type of thetemperature recorder is MTR-G85C and MTR-85H. For the attachment, the recorder fixing and recordersensor cover is necessary. Contact our sales representative or agent for the installation of a temperaturerecorder.Setting of MTR-85H1. Open the cover and let down the pen holder lever. Withthis operation, the pen point is apart from the recordingpaper.2. Pull the cartridge out of the mounted position as shownin Fig. 1 and Fig. 2.3. Set a new recording paper in place on the rear bottom ofthe cartridge. Set the hole on the recording paper in thecog of the recording paper driving assembly and feed therecording paper in the direction of the arrow by driving thecog wheel. (Fig. 3)4. Adjust the recording paper properly according to themarking of date and time.5. To replace the cartridge to the recorder, insert ithorizontally first with the slot of the cartridge on theprojection on the recorder and then set up the cartridgevertically.6. Lift up the pen holder lever and close the cover.Fig. 3Fig. 1Fig. 2Fig. 3CoverRecording indicator &Pen holder Pen holder leverCartridge