Panasonic ER-VAJT-64 Instruction Manual
パナソニック インダストリー株式会社〒571-8506 大阪府門真市大字門真1006番地https://industry.panasonic.com/<FAデバイス技術相談窓口>TEL:0120-394-205受付時間:平日の9時~12時、13時~17時(土日祝日、年末年始、当社休業日を除く)Panasonic Industry Co., Ltd. 20242024年4月発行 PRINTED IN JAPANPanasonic Industry Co., Ltd.1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japanhttps://industry.panasonic.com/Please visit our website for inquiries and about our sales network.Panasonic Industry Co., Ltd. 2024April, 2024 PRINTED IN JAPAN5 オプション(別売)について● 導電性チューブ型 式 名 ER-AT50長 さ 500mm (任意の長さに切断可能)外 径 × 内 径 Φ6×4mm最 小 曲 げ 半 径 15mm材 質 ウレタン● 導電性チューブホルダ型 式 名 ER-ATH内 容 導電性チューブ(ER-AT50)の先端が動かないよう固定するために、使用します。(注1): 詳しい内容につきましては、導電性チューブホルダの取扱説明書をご参照ください。6 外形寸法図(単位:mm)● ER-VAJT-6417.847.5±3● ER-VS本体装着図47.5±3146.8±418.8272810011.74.317.89.4ワンタッチ継手部(φ6×4用)2-φ4.5取付穴ER-AT50差込口INSTRUCTION MANUALThank you very much for purchasing Panasonic prod-ucts. Read this Instruction Manual carefully and thor-oughly for the correct and optimum use of this product.Kindly keep this manual in a convenient place for quickreference.Exclusive Nozzle for ER-VS SeriesConductive tube joint nozzleER-VAJT-64MJEC-ERVAJT64 No.0099-21V1 OUTLINE● This product is the exclusive nozzle for the ultra-compact ionizer spot type (ER-VS Series).● In order to use this product, the conductive tube (ER-AT50) (optional) is required.2 SPECIFICATIONSDesignation Conductive tube joint nozzleModel No. ER-VAJT-64Air pressure range 0.02 to 0.4MPa(Max. applicable pressure depends on the tube length. Refer to the right figure)Material Stainless steelConsumption air flow 20 to 100 /min. (ANR) (at applied pressure of 0.02 to 0.4MPa)Accessories Attachment (White): 1pc., Insulating pipe: 1pc.0.40.30.2100 300 50003 MOUTING● On the ultra-compact ionizer spot type (ER-VS Series), a protective film is affixed on the nozzle fitting part.Be sure to remove it before fitting the nozzle.● The insulating pipe and the attachment are enclosed with the nozzle. Mount them as decribed below.Procedure1. Insert the insulating pipe into the center of the nozzle(ER-VAJT-64). (Note 1)2. Direct the convex part of the center of the attachment towardsyou (see the right figure) and inserted it into ER-VS main unit.3. In the state of 1,insert them into the nozzle fitting part ofER-VS main unit. (Note 1)4. Mount the nozzle into the nozzle fitting part of ER-VS mainunit.The tightening torque should be 6N・m or less.5. Insert the conductive tube (ER-AT50) (optional) into the one-touch joint section of the nozzle. (Note 2)Notes: 1) Be sure to fit the insulating pipe and the attachment. When they are not fitted,the static removal efficiency deteriorates considerably.2) After connecting the conductive tube, pull it toward you to make sure it does notdetach. If the tube disconnects, pull the one-touch joint section toward you andreconnect the tube securely. After the reconnection, pull the tube toward youagain to confirm that it does not disconnect.ER-VS main unitProtective filmConvex partOne-touch jointsection (for ø6 × 4)Conductive tube (ER-AT50) (Optional)Conductive tube joint nozzle(ER-VAJT64) (for ø6 × 4)(Accessory)AttachmentInsulating pipe123454 CAUTIONS● This product has been developed / produced for industrial use only.● Use the product by the air pressure according to the tube length.● The static removal efficiency depends upon the air pressure value. Use the product by the appropriate air pressure.● The longer the conductive tube (ER-AT50), the less effective the static removal efficiency. Cut off the tube at the desiredlength to meet your conditions for use.● Use an attachment suitable for nozzle.● The conductive tube (ER-AT50) is consumables. Replace it when fading or cracking etc. due to deterioration is found.5 OPTIONAL● Conductive tubeModel No. ER-AT50Length 500mm (cuttable at desired length )Outer diameter × inner diameter Φ6×4mmMinimum bending radius 15mmMaterial Urethane● Conductive tube holderModel No. ER-ATHDescription This is used for fixing the tip of theconductive tube (ER-AT50).Note: For details, refer to the instruction manual enclosed with the conductive tube holder.6 DIMENTIONS (Unit: mm)● ER-VAJT-6417.847.5±3● Mounting drawing with ER-VS main unit47.5±3146.8±418.8272810011.74.317.89.4One-touch jointsection (for ø6 × 4)2-ø4.5 mouting holesER-AT50 inlet取 扱 説 明 書このたびは、パナソニック製品をお買い上げいただき、ありがとうございます。ご使用の前にこの取扱説明書をよくお読みになり、正しく最適な方法でご使用ください。尚、この取扱説明書は大切に保管してください。ER-VSシリーズ 専用ノズル導電性チューブジョイントノズルER-VAJT-641 概要● 超小型イオナイザ・スポットタイプ(ER-VSシリーズ)の専用ノズルです。● 本製品をご使用になるには、別売の導電性チューブ(ER-AT50)が必要です。2 主な仕様品 名 導電性チューブジョイントノズル型 式 名 ER-VAJT-64エ ア 圧 力 範 囲 0.02 to 0.4MPa(最大印加圧力は、チューブ長による。右図参照)材 質 ステンレス消 費 エ ア 流 量 20 to 100 /min. (ANR) (印加圧力0.02~0.4MPa)付 属 品 アタッチメント(白色):1個、絶縁パイプ:1個0.40.30.2100 300 50003 取り付け● 超小型イオナイザ・スポットタイプ(ER-VSシリーズ)には、ノズル取付部に保護フィルムが貼ってあります。必ず剥がしてからノズルを取り付けてください。● ノズルには、絶縁パイプおよびアタッチメントが付属されています。下記のように取り付けてください。手順1. ノズル(ER-VAJT-64)の中心部に絶縁パイプを差し込みます。(注1)2. アタッチメントをアタッチメント中心部の凸部を手前(右図参照)にして、ER-VS本体へ挿入します。(注1)3. 1の状態でER-VS本体のノズル取付部に挿入します。4. ノズルをER-VS本体ノズル取付部に取り付けます。そのときの締め付けトルクは、6N・m以下としてください。5. 別売の導電性チューブ(ER-AT50)をノズルのワンタッチ継手 部 に 挿入してください。(注2)ER-VS本体保護フィルム凸部ワンタッチ継手部(φ6×4用)導電性チューブ(ER-AT50)(別売)導電性チューブφ6×4用ジョイントノズル(ER-VAJT64)(付属)アタッチメント絶縁パイプ12345(注1): 絶縁パイプおよびアタッチメントは、必ず取り付けてください。取り付けない場合、除電性能が著しく低下します。(注2): チューブ装着後、必ずチューブを手前に引いて、チューブが抜けないことを確認してください。チューブが抜ける場合は、ワンタッチ接手部を手前に引いてからチューブを再度装着してください。装着後は再びチューブを手前に引いて、抜けないことを確認してください。4 注意事項● 本製品は、工業環境に使用する目的で開発/製造された製品です。● チューブ長に適したエア圧力でご使用ください。● エア圧力値により、除電効果が異なります。最適なエア圧力でご使用ください。● 導電性チューブ(ER-AT50)は長くなる程、除電効果が低下します。ご使用になる条件に合わせて適切な長さに切断してください。● 適用アタッチメントは、必ずノズルに合ったものをご使用ください。● 導電性チューブ(ER-AT50)は消耗品です。劣化による変色またはひび割れなどが確認された場合は、交換してください。7.77.7Max.applicablepressure (MPa)Tube length(mm)チューブ長(mm)最大印加圧力(MPa) |
Related manuals for Panasonic ER-VAJT-64
Panasonic SF4C Series Instruction Manual
Panasonic PAW-160MAH2L Installation Instructions Manual
Panasonic VR2 Series Operating Instructions Manual
Panasonic RV10C-M KXF-6Q3C Operating Instructions Manual
Panasonic YA-1W Series Operating Instructions Manual
Panasonic ERG12D Manual
Panasonic 60A Operation Manual
Panasonic ERA V Series Manual
Panasonic EXC34CE Manual
Panasonic EXCX4CZ Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved