Panasonic DP-100 Series Instruction Manual
Also see for DP-100 series: Instruction manualInstruction manualInstruction manual
Contents |
INSTRUCTION MANUALHigh-performance Digital Display Pressure SensorDP-100 SeriesMJE-DP100 No.0025-36VThank you very much for purchasing Panasonic products. Read this Instruction Manualcarefully and thoroughly for the correct and optimum use of this product. Kindly keepthis manual in a convenient place for quick reference.WARNING Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products whichmeet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-tion applicable in each region or country. This product is designed for use with non-corrosive gas. It cannot be used for liq-uid or corrosive gas. A product intended for use in Japan conforms to the Japanese Measurement Act.Do not use a product intended for use overseas in Japan.1 PART DESCRIPTIONOutput 1 operationindicatorLights up when com-parative output 1 is ONOutput 2 / analoguevoltage output opera-tion indicatorStandard type:Lights up when com-parative output 2 is ONHigh-function type:Lights up when analoguevoltage output is setMode selection keyUnit display(Note 1, 2)Main displaySub displaySetting valueDOWN keySetting value UP keyConnectionconnectorPressure portDP-100 type: R1 /8 + M5 female screwDP-100-E type: G1 /8 + M5 female screwDP-100-M type: M5 female screwDP-100-N type: NPT1 /8 + M5 female screwNotes: 1) In the case of a model that is intended for use outside Japan, attach the unit switch plate corresponds to the setpressure unit.2) The product for use inside Japan can be set only to “MPa” or “kPa.”2 PIPING When connecting a commercial coupler to the pres-sure port, attach a 12mm spanner (14mm for DP-100-E port, and then tighten with a tightening torque of 9.8N·mor less (M5 female: 1N·m or less). The commercialcoupler or pressure port section will be damaged if thetightening torque is excessive.Wrap sealing tape around the coupler when connect-ing to prevent leaks.12mm spanner3 MOUNTING The sensor mounting bracket MS-DP1-1 is available as an option. When mounting the sen-sor onto the sensor mounting bracket, etc., the tightening torque should be 0.5N·m or less.M3 (length 6mm) screwswith washers(Accessory with MS-DP1-1)Sensor mounting bracketMS-DP1-1 (Optional) The panel mounting bracket MS-DP1-2 (optional) and MS-DP1-4 (optional), as wellas the front cover MS-DP1-3 (optional) and DPX-04 (optional) are also available. The type of the front cover is different depending on the applied mounting bracket.Use MS-DP1-3 for MS-DP1-2, and DPX-04 for MS-DP1-4. For mounting of the panel mounting bracket, refer to the Instruction Manual en-closed with MS-DP1-2 or MS-DP1-4.4 WIRINGConnection method Insert the cable with connector CN-14A-Cinto this product’s connection connector sec- Disconnection method Pressing the release lever of the cable withconnector, pull out the connector.Cable with connectorCN-14A-CRelease lever |
Related manuals for Panasonic DP-100 series
Panasonic DP-100 Series Instruction Manual
Panasonic DP-00 Series Instruction Manual
Panasonic DP-M Series Instruction Manual
Panasonic CY-100 Series Instruction Manual
Panasonic CY-100 Series Instruction Manual
Panasonic FX-100 Series Instruction Manual
Panasonic FX-100-Z Series Instruction Manual
Panasonic EZ-10 Series Instruction Manual
Panasonic EX-10 series Instruction Manual
Panasonic PE Series Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved