Panasonic CZ-NS4P Installation Manual
SAFETY PRECAUTIONS• Read the following “SAFETY PRECAUTIONS” carefully before installation.• Electrical work must be installed by a licensed electrician.• The caution items stated here must be followed because these important contents are related to safety.The meaning of each indication used is as below. Incorrect installation due to ignoring of the instruction willcause harm or damage, and the seriousness is classified by the following indications.WARNING This indication shows the possibility of causing death or serious injury.CAUTION This indication shows the possibility of causing injury or damage to propertiesonly.The items to be followed are classified by the symbols:Symbol with white background denotes item that is PROHIBITED from doing.Symbol with dark background denotes item that must be carried out.• Carry out test run to confirm that no abnormality occurs after the installation. Then, explain to user theoperation, care and maintenance as stated in instructions. Please remind the customer to keep theoperating instructions for future reference.Optional PCB Installation ManualF616881Electric CircuitWARNING1) Be sure to turn off all power supply before installing and connecting the Optional PCB. Otherwise, itwill cause electrical shock.2) Engage authorized dealer or specialist for installation. Defective installation will cause electrical shockor fire.3) Strictly follow this installation instruction when doing installation work. Defective installation will causeelectrical shock or fire.4) Use the attached accessories parts and specified parts for installation. Otherwise, it will causeelectrical shock or fire.5) For electrical work, follow local national wiring standard, regulation and this installation instruction.Otherwise, it will cause electrical shock or fire.6) Wire routing must be properly arranged so that control board cover is fixed properly. If control boardcover is not fi xed properly, it will cause electrical shock or fire.7) Do not modify the length of Optional PCB lead wires. Otherwise, it will cause abnormal operation,electrical shock or fire.8) Do not touch the Optional PCB once the power supply is turn on. Accidental contact with the OptionalPCB will cause electrical shock.Optional PCB InstallationBefore installing the Optional PCB, steps below need to be carried out to remove the exterior chassis.WARNINGBe sure to switch off all the power supply (i.e. indoor power supply, heater power supply, boilertank power supply) before performing the steps below to avoid electrical shocks, etc.Step 1: Removal of the Cabinet Front PlatePlease follow the steps below for take out front plate. Before removing the front plate of indoor unit, alwaysswitch off all power supply (i.e. indoor unit power supply, heater power supply and Tank Unit power supply).1. Remove the 2 mounting screws which located at bottom of the front plate.2. Gently pull the lower section of the front plate towards you to remove the front plate from left and righthooks.3. Hold the left edge and right edge of front plate to lift up front plate from hooks.HookLift upScrewsStep 2: Open the Control Board CoverPlease follow the steps below to open control board cover. Before opening the control board cover ofindoor unit, always switch off all power supply (i.e. indoor unit power supply, heater power supply and TankUnit power supply).1. Remove the 6 mounting screws at the control board cover.2. Swing the control board cover to the right hand side.ScrewsScrewsCAUTIONStep 3: Installing the Optional PCB 1 onto the Control Board1. Refer to the figures below, tighten Holder 4 and Holder 5 onto the control board with Screw 6.2. Fix the Spacer 2 and Spacer 3 onto the control board. Then fix and push to hook the Optional PCB ontothe Spacer 2 and Spacer 3.Spacer 3- 16pcsSpacer 2Spacer 2 - 6pcsOptional PCB 1Make sure holes ofOptional PCB 1(6 locations) arefully insert into theSpacer 2OptionalPCB 1Push tohookHolder 4- 5pcsScrew 6- 5pcs Holder 5- 5pcsScrew 6- 5pcsControlBoardStep 4: Connecting Optional PCB 1 lead wires to the Main PCB1. Connect the lead wires from ACN (WHT) & ACL (BLK) (from Optional PCB 1) to CN-PWR (BLK) (fromMain PCB).2. Connect the lead wires from CN-COMM (YLW) (from Optional PCB 1) to CN-CNT (WHT) (from MainPCB).3. Connect the lead wires from CN-PWR202 (YLW) (from Optional PCB 1) to CN-PWR2 (BLU) (fromMain PCB).4. Connect the lead wires from CN-PWR204 (YLW) (from Optional PCB 1) to CN-PWR4 (BLK) (fromMain PCB).5. Connect the lead wires from DCN (BLU) & DCP (RED) (from Optional PCB 1) to CN-PWR3 (GRN)(from Main PCB).6. Make sure all connections are fixed securely.7. Guide all lead wires as shown in the figures below.Optional PCB 1Main PCBMain PCB*For WH-SDC03H3E5 and WH-SDC05H3E5 onlyDCN(BLU)DCP(RED)CN-PWR204 (YLW)CN-PWR2 (BLU)CN-PWR3 (GRN) CN-PWR (BLK) CN-PWR4 (BLK) CN-CNT (WHT)CN-PWR3 (GRN)CN-CNT (WHT)CN-PWR (BLK)CN-PWR4 (BLK)CN-COMM (YLW)CN-PWR2 (BLU)CN-PWR202 (YLW)ACL (BLK)ACN(WHT)PRINTED IN MALAYSIAF616881ENGLISH1 14Attached AccessoryNo. Accessory Part Qty. No. Accessory Part Qty.1Optional PCB (CZ-NS4P)14Holder55Holder52Spacer6 6Screw103Spacer16Recommended Specifications of Field Supply Accessoriesi Room thermostat Wired PAW-A2W-RTWIRED AC230V -Wireless PAW-A2W-RTWIRELESSii Mixing valve - 167032 AC230V Caleffiiii Pump - Yonos 25/6 AC230V Wiloiv Buffer tank sensor - PAW-A2W-TSBU - -v Zone water sensor - PAW-A2W-TSHC - -vi Zone room sensor - PAW-A2W-TSRT - -vii Solar sensor - PAW-A2W-TSSO - -Water Circuit And System Installation1. Functions below are available through the connection of the Optional PCB (CZ-NS4P) to the Main PCB.• 2-zone control• Pool• Buffer tank• Solar• External error signal output• Demand control• SG ready• Stop compressor by external compressor switch• Switch heating and cooling by external Heat-Cool switch2. Please refer to the Indoor Unit installation manual for water circuit installation details and system setup details.WWWWWWWWWCN-CNT(WHT)CN-PWR2(BLU)CN-PWR (BLK)CN-PWR4(BLK)CN-PWR204(YLW)CN203N OPEN CLOSEN OPEN CLOSECN-COMM(YLW)CN-PWR202(YLW)ACN (WHT)SSR207SSR206SSR205SSR204CN202ACL (BLK)DCN(BLU)DCP(RED)CN210CN206VCCDCGNDDC1OVBIT2 BIT1CN207CN204CN205SSR201SSR200SSR203SSR202CN201L N COOL HEAT L N COOL HEATCN209CN208RY1CN-CNT(WHITE)15CN-PWR3(GRN)132241233132115111BRSIGNALDETECTIONCIRCUITSIGNALDETECTIONCIRCUIT BLREMARKS:W : WHITER : REDB : BLUEBL : BLACKMAINPCBWATERPUMPZONE 2WATERPUMPZONE 1POOLWATERPUMPEXTERNALCOMP. SWHEAT/COOLSWITCHSG SIGNALSOLAR TEMP.SENSORWATER TEMP.ZONE 1WATER TEMP.ZONE 2POOL TEMP.SENSORBUFFER TANKSENSORROOM TEMP.ZONE 1ROOM TEMP.ZONE 2DEMANDSENSORROOM THERMO 2 ROOM THERMO 1SIGNALDETECTIONCIRCUITSIGNALDETECTIONCIRCUITMIXINGVALVE 1MIXINGVALVE 2Optional PCB (CZ-NS4P)SOLARWATERPUMPERRORSIGNAL |
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved