2911.6 Powerful Mode Operation• When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/SoftDry) than remote control setting temperature for 240 minutes and the fan speed will increase to achieve thesetting temperature quickly.• Powerful operation stops conditiono When one of the following condition is satisfied, powerful operation stops: Quiet button is pressed. Mild Dry Cooling button is pressed. Stop by OFF/ON button. OFF Timer activates. Powerful button is pressed again. Powerful operation continues for 240 minutes.11.7 Timer Control11.7.1 ON Timer ControlON timer can be set using remote control, where the unit with timer set will start operation earlier than the settingtime. This is to provide a comfortable environment when reaching the set ON time.60 minutes before the set ON time, indoor (at fan speed of Lo-) and outdoor fan motor start operation for 30 secondsto determine the indoor intake air temperature and outdoor air temperature in order to judge the operation startingtime.From the above judgment, the decided operation will start operation earlier than the set time as shown below.11.7.2 OFF Timer ControlOFF timer can be set using remote control, where the unit with timer set will stop at set OFF time.Notes:1 By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.2 To cancel the previous timer setting, press CANCEL button.3 To activate the previous timer setting, press SET button.4 If main power supply is switched off, the Timer setting will be cancelled.11.8 Random Auto Restart Control• When the power supply is cut off during the operation of air conditioner, the compressor will re-operate withinthree to four minutes. There are 10 patterns to be selected randomly after power supply resumes.• This control is not applicable during OFF/ON Timer setting.15 min10 min5 minIndoor intake airtemperature (°C)302530 35Outdoor airtemperature (°C)Cooling / Soft Dry