5913.7 Horizontal Airflow Direction Control13.7.1 Auto Control• When the horizontal airflow is set to Auto using the remote control, the vanes swings left and right as shown inthe diagram.• When stopped with remote control, the discharge vanes are reset and stop at the reset position.• During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At thatcondition, the vane will stop swinging and rest at face front position.For CS-C9PK and CS-C12PKFor CS-C18PK, CS-C24PK and CS-C28PK13.7.2 Manual Control• When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is releasedand the airflow direction vane move left and right in the range shown in the diagram.• The louver can be adjusted by pressing the button to the desired vane position.• When stopped with remote control, the vanes is reset and stopped at reset position.For CS-C9PK and CS-C12PKPattern 1 2 3 4 5Airflow Direction Patterns atRemote ControlVane Angle (°) 25 50 37.5 12.5 0For CS-C18PK, CS-C24PK and CS-C28PKPattern 1 2 3 4 5Airflow Direction Patterns atRemote ControlVane Angle (°) 20 40 30 10 0