(?) Why is it possible to control the camera by this setting-up only?Default IP address for AW-XXXX is (192.168.0.10).Meanwhile, the camera IP address table (CAM IP ADR) /CAM1 provided for AW-RP50 in advance is set to(192.168.0.10).So, when the connection method for [1] CAM1 is set to [Network], AW-RP50 recognizes the camera as CAM1.☆AW-RP50: MENU > [10] SYSTEM > [7] CAM IP ADR with default setting valuesto* When AW-XXXX with its IP address set to (192.168.0.11) is connected via IP connection, if theConnection setting for [CAM IP ADR]/CAM2 is changed to [Network], this AW-XXXX is recognized as CAM2.3. Turn AW-XXXX on.(How to switch over to POWER ON mode (power ON) on AW-XXXX connected to CAM1)· Hold down LED button 1 at CAMERA STATUS/SELECTION. – (Fig. 3-A)* While the button is held down, the selected camera and its power status will be displayed on the LCDscreen.– (Fig. 4)· Keeping the button held down, turn F2 dial to select “ON”. Then press F2 dial to determine it. – (Fig. 3-B)* By this operation, AW-XXXX will be switched over to POWER ON mode after its default setting motion.(The status lamp will light up in green and the LED on AW-RP50 will also light up in green.)* When performing the same procedure from POWER ON mode, if [POWER: OFF] is selected, AW-XXXX will beswitched over to STANDBY mode.CAM1<AW-XXXX >POWER: OFFCAM1<AW-XXXX >POWER: ON1 IP: CAM1 (192.168.0.10)100 IP: CAM100 (192.168.0.109)“CAM1” is held downSelect “ON” ⇒ Press F2 to determineTurn F2(A)(Figure 3) (Figure 4)(B)② Check that the LAN cable is connected to “LAN port”, not to “RS422 port”.③ Double-check that there is no error in setting up the connection.