21G/L I N Pb OUT Pr / SDIOUTY/ VIDEOOUT1394CONTROL INIP/ RPDC12VINCAMERA I/FLENSE I/FND/EXTSDIINC S OP+ -LAMPCONTROL<;=Connections$Connecting the AC adapter for use with the pan-tilt headConnect the pan-tilt head with the AW-PS300 AC adapter designed for use with the pan-tilt head.Approx. 1 cmIt is recommended that the tip be soldered.AC adapter for use with thepan-tilt head:AW-PS300;DC 12V IN terminal boardConnect this to the DC 15V OUTconnector on the AC adapter (AW-PS300). (The voltage output from theAC adapter is set to 15V: this takes intoconsideration the voltage drops due tothe possible extension of the DC cablebetween the pan-tilt head and ACadapter.)Make sure that the positive + andnegative - ends of the wires areconnected to the same signs on theconnector.Use a cable with a nominal cross sectionof 1.25 mm 2 or more which complieswith the Electrical Appliance andMaterial Control Law for the connection.<LAMP CONTROL terminal boardConnect this only when the power of ahalogen lamp is to be supplied from theLAMP AC OUT connector on the ACadapter (AW-PS300).This connector is connected to LAMPCONTROL on the AC adapter for thepan-tilt head.The symbols C and S on the wires mustmatch the same symbols on theconnector.Use a cable with a nominal cross sectionof 0.3 mm 2 or more that complies withthe Electrical Appliance and MaterialControl Law for the connection.=OP terminal boardConnect this only when the OP SWCONTROL OUT connector on the ACadapter (AW-PS300) is to be used.Connect it to the OPTION SWCONTROL IN connector on the ACadapter (AW-PS300).Use a cable with a nominal cross sectionof 0.3 mm 2 or more that complies withthe Electrical Appliance and MaterialControl Law for the connection.