Australia Head Office: 4 Pike Street Rydalmere NSW 2116Ph+61 2 9684 1466 Fx+61 2 9684 4146 Toll Free 1300 78 FIRENew Zealand Unit 106, The Zone, 23 Edwin Street Mount Eden1024Ph+64 9 638 4644 Fx+64 9 6384645 Toll Free 0800 220 007Web: www.brooks.com.au (Aus) www.brooks.co.nz (NZ)E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. DS4414 10/11/14Sydney - Melbourne - Adelaide - Brisbane - Perth - Hobart - Darwin - New Zealandfire products and solutionsFire System TechnologyFire Panels - AccessoriesFire Alarm Systems Address Setting ToolModel 4414 Used for COM loop address and mode settingsCOM loop address settingAddress setting tool 4414 is used to set the COM loopunit's address (001-255) on the analogue detector types33xx / 430x / 440x and all other addressable COM loopunits (33xx / 43xx / 44xx).Mode settingThe address setting tool 4414 is also used to set theCOM loop unit's mode:M0 = NORMAL modeM1 = 2330 mode (COM loop address 001-127)M2 = 2312 mode (COM loop address 001-127)M3 = Advanced mode See instructions for the COM loopunit respectively.Connection cableSome units have flying leads and some units only screwterminals. A connection cable with insulated crocodileclips and push-on terminals is supplied with the addresssetting tool, to be used for the COM loop units thatcannot be plugged directly on the tool.Product applicationsUsed for address and mode settings when analoguedetectors and other addressable COM loop units are tobe used in the systems FT128V2 and FT1020G3.4414 has to be used to set the analogue detectors 440xin Advanced mode.User friendlyThe address setting tool is powered by four 1.5 V Alkalinebatteries (LR6 / AA). Battery life time is approx. 250 hours orup to 50000 readings / writings.An analogue detector's contact pins (SA / SB) are plugged intothe address setting tool's snap connectors (SA / SB). Theconnection cable is used to connect to other units.The tool is turned on by the On/Off / CLR button. "MØ" and ablinking cursor will be shown in the display.How to read:Turn on the tool.Press the Read button.Wait for a beep ("READ" will be shown in the display)."OK", the address and the mode will be shown in the display.How to write:Turn on the tool.Default mode is M0 (NORMAL mode). The mode can bechanged by pressing the Write and Read buttons at the sametime and then select a mode (0-3).Type the COM loop address (001-255)Press the Write button.Wait for a beep ("WRITE" will be shown in the display)."OK", the address and the mode will be shown in the display.Write the COM loop address on the Address label on the COMloop unit respectively.If the tool is not used for approx. 20 seconds, it will beautomatically turned off in order to save the batteries.