CONFIGURATION35 of 12Type PGN No ParametersJ1939 PGNs PGN61443 Engine Percent LoadPGN61444 Engine SpeedPercent TorquePGN65270 Engine Turbocharger Boost PressurePGN65262 Engine Oil TemperatureEngine Coolant TemperaturePGN65271 Alternator Potential (Voltage)PGN65266 Engine Fuel RatePGN65253 Engine Total Hours OperationPGN65263 Engine Coolant PressureEngine Fuel Delivery PressureEngine Oil PressurePGN65214 Engine Rated SpeedPGN65260 Vehicle Identification NumberPGN65242 Software IdentificationThe following two items can be configured directly on the 3185 using the two small rotaryswitches. There are no other menu setups to worry about.3.1 J1939 SourceThe J1939 Source dial is now redundant to the design and does not require setting to a specificsetting. Dial can be set to 0 as a precaution.3.2 NMEA2000® Device InstanceEach 3185 J1939 to NMEA2000® Adaptor connected to the NMEA2000® network needs to havea unique Device Instance Address. The Device Instance of each unit is set by turning the smallrotary switch with a small screw driver. Valid Device Instances range from “0” through to “F”.J1939 Data Translated to NMEA2000®0FEDCBA987654321