NBE RTB 10 Manual
Ready To BurnReady To Burn: Version 1.0 October 2015 Page 17 of 24FIRST TIME START UPOnce the system is assembled, filled with water, supplied with power and pellets a few basicadjustments to the burner are required. Step 1 is to calibrate the external auger by weighingthe wood pellet delivery. Step 2 is adjusting the fan setting at 10%, 50% and 100% powerto obtain the desired O2 and CO2 readings.Step 1: Weighing the pellets1. Detach the drop hose from the drop tube on the burner andattach a plastic bag or similar underneath the drop hose(seeimage on right.)2. Go to the menu Manual Control>External Auger>ON.This will force start the external auger. Allow the auger to runfor approximately 15 minutes. This will ensure that the augeris completely filled and will allow for a more accurate weighinglater. Once complete discard the pellets from the plastic bagand refasten the empty plastic bag to the drop hose.3. Go to the menu Auger>Balancing>360s to activate the 360 second test. Woodpellets will begin dispensing.4. When the test is complete, remove the plastic bag, and weigh thepellets on a kitchen scale. Enter the weight in the controller by goingto the menu Auger>Auger capacity/6 min> enter“pellet weight”Step 2: Adjusting the Fan1. Turn on the system by pressing the ON/OFF button on the controller.2. Go to the Regulation menu> set Min power=100% & Max power= 100%. Thiswill lock output to 100% power. Allow 15 minutes for the burner to reach 100%output.(Note: when locking output to 50% power, set Min & Max power = 50%.Similarly, when locking output at 10%, set Min & Max power=10%)3. Take a measurement of either the CO2% or O2% in the chimney using a flue gasanalyzer and ensure that the CO2% or O2% at 100% power are within range to thevalues shown in the table below.Power O2% CO2%10% 7-9 12-1450% 11-13 8-10100% 15-17 4-6If the O2% reading is too low, (or if the CO2% is too high) compared to the valueson the table, then increase the fan speed to increase the O2% and decrease theCO2% in the combustion. Similarly, to decrease the O2% and increase the CO2%,decrease the blower speed. To adjust the blower speed, go to the Fanmenu>Speed at 100% power and adjust the blower speed by a few % at a time.Allow a few minutes for the adjustment to take effect. Take an O2% or CO2%reading and confirm that the values shown are within the range of the values shownin the table.4. Repeat steps 1-3 to adjust the blower speed at 50% and 10% power. Rememberreset Min power=10% and Max power=100% before normal operation. |
Related manuals for NBE RTB 10
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved