Hexadecimal Data EntryTo Enter a hexadecimal digitenter the following:A= D= B= E= C= F= Set KeyPress this key beforeentering a Program-ming Block Number.XP-600 Programming Instructions®DEALER PROGRAM MODE - KEYPAD KEY DEFINITIONNote: These Programming Instruction are intended to be used in conjunction with WI847C,please refer to WI847C for additional information, instructions and definitions.Exiting Dealer Program Mode(4) (5) (6) (7)Dealer CodeEnter Enter +Default Dealer Code shown in parentheses(4) (5) (6) (7)Dealer CodeBlank KeyPress this key to disable all fea-tures within a LED type Program-ming Block or to blank out digits ina Direct Entry type ProgrammingBlock.1. Remove power from the panel.2. Remove all wiring from terminal15 (PGM) and terminal 3.3. Connect terminal 15 (PGM) toterminal 3.4. Apply power to the XP-600 con-trol panel.5. After a few seconds the ARMED,READY and *SYSTEM TROU-BLE LEDs will flash.6. The keypad will beep 3 timesindicating the panel default val-ues have been loaded.7. Remove wiring between terminal15 (PGM) and terminal 3.8. Re-install original wiring for ter-minal 15 (PGM) and terminal 3.Note: Any programming inDealer Options 1 [96] andDealerOptions 2 [97] will not be de-faulted. IfDealer Code Lockouthas been programmed the panelwill not default the Dealer Code.The Event Log will be erasedwhen the panel is defaulted.D EFAULTING THE P ANEL$50('5($'<6<67(0**),5($&=21( =21( =21( =21( =21( =21( 1$3&2 Scroll KeyUse this key to scrollthrough data that has beenentered in ProgrammingEntering Dealer Program Mode READYARMED ONOFFFLASHINGIndicates the panel is in DealerProgram Mode. The panel isready for a programming blocknumber to be entered.SYSTEM9READYARMED FLASHINGFLASHINGFLASHINGIndicates the panel isReady to exit DealerProgram Mode. Enterthe Dealer Code to exit.SYSTEM9Entering Dealer Program Mode is not permitted while the panelis Armed, Reporting, or the Bell Output is on. To Enter DealerMode while the Bell is ON or the panel is Reporting or Armed;power up the panel and enter Dealer Mode within the first 3minutes. Pressing the " key clears the 3 minute timer.NOTE:After 15 minutes of keypad inactivity the keypadwill emit a steady tone indicating the panel has beenleft in Dealer Program Mode. Enter Dealer Code toexit or press the key to return to DealerProgram mode.NOTE: