WI1372 XP-600 Installation Instructions[15]Line Cut Time-to-FailEnable this feature by programming thedelay time required to declare a line cutfailure. Programming 000 will disable linecut detection.[16]Wireless Supervisory TimerA transmitter will send a transmission everytime it is tripped; when there is no activity,the transmitter sends a supervisorytransmission about once an hour. If thereceiver does not receive any signal (eithera trip or a status) from a transmitter in thetime specified, a system trouble ëRFSupervisory Failure' will be indicated at thekeypad. Timer is programmable from 1-26hours; 0 means NO supervision.[17]Wireless Smoke Supervisory TimerA smoke detector will send a transmissionevery time it is tripped; when there is NOactivity, the smoke detector sends asupervisory transmission about once anhour. If the receiver does not receive asignal (either a trip or a status) from atransmitter in the time specified, a systemtrouble ëRF Supervisory Failure' will beindicated at the keypad. The Supervisorytimer is programmable from 1-8 hours; 0means NO supervision.[18]Test Timer OffsetEnter the time, in hours, that a Test Timerwill be reported after Dealer Mode has beenexited. With the default value of 12, the testtimer will be sent 12 hours after exitingDealer Mode. The test timer can also beoffset using NAPCO PCD3000 DownloadingSoftware. On power up the test timer is sentimmediately. Follow the commands belowto offset the test timer using QuickloaderSoftware:From the Status Screen• Press F6• Select Miscellaneous Control• Select Test Timer Offset• Enter New Test Timer Offset: 12hours• Enter u to advance the test timerdue in time by 12 hours.System Features[20]Keypad Features 1(1) Enable Keypad Fire (ee)Additional Programming required:Select reporting to Telco 1 [36-1] or Telco 3[56-1].(2) Enable Keypad AUX (ff)Additional Programming required:Select reporting to Telco 1 [36-2] or Telco 3[56-2].(3) Enable Keypad Panic (gG)Additional Programming required:Select reporting to Telco 1 [36-3] or Telco 3[56-3].(4) Enable Ambush - If enabled, the 6thUser Code will send an Ambush reportwhen entered to disarm the system.Additional Programming required:Program User 6 Arm/Disarm Code.Select reporting to Telco 1 [36-2] or Telco 3[56-2].UL Installations: If Keypad Fire [20-1] isenabled, the keypad must be mountedwithin (3) three feet from the Control Panel.[21]Keypad Features 2(1) Audible Panic - Keypad Panic will notturn the Bell on unless this option isprogrammed.(2) Exit/Entry with Urgency - select to givean audible indication of Exit and Entry times.During the last 10 seconds of entry and exittime, the keypad sounds a distinct sound toindicate the premises must be left or thepanel must be disarmed.(3) Display Bypassed (Armed) - Select todisplay bypassed zones while the panel isarmed.(4) Disable Code Entry Beeps - Programto disable keypad beeping on valid code andfunction entries.