Mitsubishi Electric MAC-1702RA-U Installation Manual
This product is an adapter which outputs the ON/OFF signals from theair conditioner to the backup heater.CN24 (Coil rating of DC 12V,1W or less.) Userelay with reinforcedinsulationRelay1. Outline2. Backup heating functionIndoor electronicP.C. board1. How to connect the relay• Connect the connector to CN24 on the indoor electronic P.C. board.• Connect the electrical wires to the relay.2. Operation details(1) Starting conditionsWhen both a) and b) are satisfied, the relay turns ON.a) The HEAT mode is selected. (The unit operates in the HEAT modewhen the AUTO operation is selected.)b) In the figure below, the conditions for ON are satisfied. (NOTE1)(2) Releasing conditionsWhen either a) or b) is satisfied, the relay turns OFF.a) The modes other than HEAT are selected. (The unit operates inthe mode other than HEAT when the AUTO operation is selected.)b) In the figure below, the conditions for OFF are satisfied. (NOTE1)Backup heatingfunctionAmbient temperature(Default)Ambient temperature(During operation)Enabled 50 °F (10 °C ) or lessDisabled more than 50 °F (10°C ) 50 °F (10 °C ) 68°F (20 °C )Relay(heater)Room temperatureminus set temperature(Initial)Room temperatureminus set temperature(During operation)ON -3 °F (-1.5°C ) or lessOFF more than -3 °F (-1.5°C )-3°F (-1.5°C ) -1 °F (-0.5°C )Installation manualEnglishModels MAC-1702RA-UMAC-1710RA-U[FOR INSTALLER]INSTALLATION MANUALCONNECTION MANUAL[POUR L’INSTALLATEUR]MANUEL D’INSTALLATIONMANUEL DE BRANCHEMENT[PARA EL INSTALADOR]MANUAL DE INSTALACIÓNMANUAL DE CONEXIÓNHEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANPrinted in ThailandJG79A895H01Connector Cable (CN24)CN24For details on the cable layout, refer to “Connecting anINTERFACE/CONNECTOR CABLE to the air conditioner”Provided with Indoor unit of the air conditioner.2. Connecting an connector cable to the air conditionerModels for which the mountingcord clamp is usedModels for which the fasteneris usedFastenerMountingcord clampConnection manual1. AccessoryPart name Illustration Q' tyMounting cordclamp 1Screw formounting4×16 1Fastener(for bundling thewires) 1NOTE1:The Backup heating function changes to be enabled or disabled according tothe ambient temperature.Relay (heater) turns ON or OFF by the difference between the roomtemperature and the set temperature.CN24Flow chart for setting the ambient temperature to enable/disable the backup heating functionEntering the setup mode for the ambient temperature to enable/disable the functionTurn ON the power supply. |
Related manuals for Mitsubishi Electric MAC-1702RA-U
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved