Mitsubishi Electric Got1000 GT1455-QTBDE General Description Manual
JY997D43901HSafety Precaution (Read these precautions before using.)Before using this product, please read this manual and the relevant manualsintroduced in this manual carefully and pay full attention to safety to handle theproduct correctly.The precautions given in this manual are concerned with this product.In this manual, the safety precautions are ranked as "WARNING" and"CAUTION".Depending on circumstances, procedures indicated by "CAUTION" may also belinked to serious results.In any case, it is important to follow the directions for usage.Indicates that incorrect handling may cause hazardousconditions, resulting in death or severe injury.Indicates that incorrect handling may cause hazardousconditions, resulting in medium or slight personal injuryor physical damage.DESIGN PRECAUTIONS Some failures of the GOT or cable may keep the outputs on or off.An external monitoring circuit should be provided to check for output signalswhich may lead to a serious accident.Not doing so can cause an accident due to false output or malfunction. If a communication fault (including cable disconnection) occurs duringmonitoring on the GOT, communication between the GOT and PLC CPU issuspended and the GOT becomes inoperative.A system where the GOT is used should be configured to perform anysignificant operation to the system by using the switches of a device otherthan the GOT on the assumption that a GOT communication fault will occur.Not doing so can cause an accident due to false output or malfunction. Do not use the GOT as the warning device that may cause a seriousaccident. An independent and redundant hardware or mechanical interlock isrequired to configure the device that displays and outputs serious warning.Failure to observe this instruction may result in an accident due to incorrectoutput or malfunction. Incorrect operation of the touch switch(s) may lead to a serious accident if theGOT backlight is gone out. When the GOT backlight goes out, the POWERLED flickers (green/orange) and the display section turns black and causesthe monitor screen to appear blank, while the input of the touch switch(s)remains active. This may confuse an operator in thinking that the GOT is in"screensaver" mode, who then tries to release the GOT from this mode bytouching the display section, which may cause a touch switch to operate.Note that the following occurs on the GOT when the backlight goes out.- The POWER LED flickers (green/orange) and the monitor screen appearsblank The display section is an analog-resistive type touch panel.If you touch the display section simultaneously in 2 points or more, the switchthat is located around the center of the touched point, if any, may operate.Do not touch the display section in 2 points or more simultaneously.Doing so may cause an accident due to incorrect output or malfunction. When programs or parameters of the controller (such as a PLC) that ismonitored by the GOT are changed, be sure to reset the GOT or shut off thepower of the GOT at the same time.Not doing so can cause an accident due to false output or malfunction.DESIGN PRECAUTIONS When the security of the GOT and relevant information need to be protectedagainst illegal access from an external device via the Internet, take measures atthe user's discretion.Failure to do so may cause the configured information to be read out illegally.DESIGN PRECAUTIONS Do not bundle the control and communication cables with main-circuit, power orother wiring.Run the above cables separately from such wiring and keep them a minimum of100mm (3.94in.) apart.Not doing so noise can cause a malfunction. Do not press the GOT display section with a pointed material as a pen or driver.Doing so can result in a damage or failure of the display section. When using the GOT with Ethernet connection, available IP addresses arerestricted depending on the system configuration.- When connecting two or more GOT units to the Ethernet network:Do not specify the IP address "192.168.0.18" to the GOT or any connectedequipment.- When connecting one GOT unit to the Ethernet network:Do not specify the IP address "192.168.0.18" to any connected equipmentother than the GOT.If the IP address "192.168.0.18" is specified in the above system configuration,IP address overlap occurs when the GOT is started up, and adverse effectmay be given to communication in the equipment in which the IP address"192.168.0.18" is set. Operation executed at IP address overlap variesdepending on the equipment and system. Turn on the power of the connected equipment and network equipment, andmake them ready for communication before connecting them to the GOT.If the connected equipment and network equipment are not ready forcommunication, a communication error may occur in the GOT.MOUNTING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the systembefore mounting or removing the GOT to/from the panel.Not doing so can cause the unit to fail or malfunction.MOUNTING PRECAUTIONS Use the GOT in the environment that satisfies the general specificationsdescribed in this manual. Not doing so can cause an electric shock, fire,malfunction or product damage or deterioration. When mounting the GOT to the control panel, tighten the mounting screws in thespecified torque range. Undertightening can cause the GOT to drop, short circuitor malfunction, and deteriorate the waterproof effect and oilproof effect.Overtightening can cause a drop, short circuit or malfunction due to the damageof the screws or the GOT, and deteriorate the waterproof effect and oilproof effectdue to distortion of the protective cover for oil, GOT or panel. Never drop cutting chips and electric wire chips into the ventilation window of theGOT when you drill screw holes or perform wiring.Otherwise, fire, failure or malfunction may be caused. When inserting/removing a SD card into/from the GOT, turn the SD card accessswitch off in advance. Failure to do so may corrupt data within the SD card. When removing a SD card from the GOT, make sure to support the SD card byhand, as it may pop out. Failure to do so may cause the SD card to drop from theGOT and break. When installing a USB memory to the GOT, make sure to install the USB memoryto the USB interface firmly.Failure to do so may cause a malfunction due to poor contact. Before removing the USB memory from the GOT, operate the utility screen forremoval. After the successful completion dialog box is displayed, remove thememory by hand carefully. Failure to do so may cause the USB memory to drop,resulting in a damage or failure of the memory. Operate and store the GOT in environments without direct sunlight, hightemperature, dust, humidity, and vibrations. When using the GOT in the environment of oil or chemicals, use the protectivecover for oil.Failure to do so may cause failure or malfunction due to the oil or chemicalentering into the GOT.WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the systembefore wiring. Failure to do so may result in an electric shock, product damage ormalfunctions. Please make sure to ground FG terminal of the GOT power supply section byapplying 100 or less which is used exclusively for the GOT. Not doing so maycause an electric shock or malfunction.WIRING PRECAUTIONS Correctly wire the GOT power supply section after confirming the rated voltageand terminal arrangement of the product. Not doing so can cause a fire or failure. Tighten the terminal screws of the GOT power supply section in the specifiedtorque range. Undertightening can cause a short circuit or malfunction.Overtightening can cause a short circuit or malfunction due to the damage of thescrews or the GOT. Exercise care to avoid foreign matter such as chips and wire offcuts entering theGOT. Not doing so can cause a fire, failure or malfunction.WIRING PRECAUTIONS The cables connected to the unit must be run in ducts or clamped.Not doing so can cause the unit or cable to be damaged due to the dangling,motion or accidental pulling of the cables or can cause a malfunction due to acable connection fault. When unplugging the cable connected to the unit, do not hold and pull the cableportion.Doing so can cause the unit or cable to be damaged or can cause a malfunctiondue to a cable connection fault. Plug the communication cable into the connector of the connected unit andtighten the mounting and terminal screws in the specified torque range.Undertightening can cause a short circuit or malfunction. Overtightening cancause a short circuit or malfunction due to the damage of the screws or unit.TEST OPERATIONPRECAUTIONS Before performing the test operations of the user creation monitor screen (suchas turning ON or OFF bit device, changing the word device current value,changing the settings or current values of the timer or counter, and changing thebuffer memory current value), read through the manual carefully and makeyourself familiar with the operation method.During test operation, never change the data of the devices which are used toperform significant operation for the system. False output or malfunction cancause an accident.STARTUP/MAINTENANCEPRECAUTIONS When power is on, do not touch the terminals.Doing so can cause an electric shock or malfunction. Connect the battery correctly. Do not discharge, disassemble, heat, short, solderor throw the battery into the fire. Incorrect handling may cause the battery togenerate heat, burst or take fire, resulting in injuries or fires. Before starting cleaning or terminal screw retightening, always switch off thepower externally in all phases. Not switching the power off in all phases cancause a unit failure or malfunction. Undertightening can cause a short circuit ormalfunction. Overtightening can cause a short circuit or malfunction due to thedamage of the screws or unit.STARTUP/MAINTENANCEPRECAUTIONS Do not disassemble or modify the unit.Doing so can cause a failure, malfunction, injury or fire. Do not touch the conductive and electronic parts of the unit directly.Doing so can cause a unit malfunction or failure. The cables connected to the unit must be run in ducts or clamped.Not doing so can cause the unit or cable to be damaged due to the dangling,motion or accidental pulling of the cables or can cause a malfunction due to acable connection fault. When unplugging the cable connected to the unit, do not hold and pull the cableportion. Doing so can cause the unit or cable to be damaged or can cause amalfunction due to a cable connection fault. Do not drop or apply any impact to the battery.If any impact has been applied,discard the battery and never use it.The battery may be damaged by the drop or impact. Before touching the unit, always touch grounded metal, etc. to discharge staticelectricity from human body, etc.Not doing so can cause the unit to fail or malfunction. Replace battery with GT11-50BAT by Mitsubishi electric Co. only.Use of another battery may present a risk of fire or explosion. Dispose of used battery promptly.Keep away from children. Do not disassemble and do not dispose of in fire.DISPOSAL PRECAUTIONS When disposing of the product, handle it as industrial waste. When disposing of batteries, separate them from other wastes according to thelocal regulations.(For details of the battery directive in EU member states, refer GOT User'sManual.)Associated ManualsThe following manuals are relevant to this product. When these loose manualsare required, please consult with our local distributor.*1 Stored in the GT Works3/GT Designer3 in PDF format.For details of a PLC to be connected, refer to the PLC user's manual respectively.Bundled ItemsTOUCH PANELPRECAUTIONS For the analog-resistive film type touch panels, normally the adjustment isnot required.However, the difference between a touched position and the object positionmay occur as the period of use elapses.When any difference between a touched position and the object positionoccurs, execute the touch panel calibration. When any difference between a touched position and the object positionoccurs, other object may be activated.This may cause an unexpected operation due to incorrect output ormalfunction.TRANSPORTATIONPRECAUTIONS When transporting lithium batteries, make sure to treat them based on thetransport regulations.(Refer to User's Manual for details of the regurated models.) Before transporting the GOT, turn the GOT power on and check that thebattery voltage status is normal on the Time setting & display screen (utilitiesscreen). In addition, confirm that the adequate battery life remains on therating plate.Transporting the GOT with the low battery voltage or the battery the reachedbattery life may unstabilize the backup data unstable during transportation. Make sure to transport the GOT main unit and/or relevant unit(s) in themanner they will not be exposed to the impact exceeding the impactresistance described in the general specifications of this manual, as they areprecision devices. Failure to do so may cause the unit to fail.Check if the unit operates correctly after transportation.Manual name Contents Manual Number(Model Code)GT14 User’s Manual(sold separately)D e s c r i b e s t h e G T 1 4 h a r d w a r e -relevant content such as part names,external dimensions, mounting, powersupply wiring, specifications, andintroduction to option devicesJY997D44801(09R823)GT Designer3Version1 ScreenDesign Manual(For GOT1000S e r i e s )(Fundamentals)1/2, 2/2(sold separately) *1D e s c r i b e s m e t h o d s o f t h e G TDesigner3 installation operation, basicoperation for drawing and transmittingdata to GOT1000 seriesSH-080866ENG(1D7MB9)GT Designer3Version1 ScreenDesign Manual(For GOT1000Series) (Functions)1/2, 2/2(sold separately) *1Describes specifications and settingsof the object functions used in GTDesigner3SH-080867ENG(1D7MC1)ProductName Model Name SpecificationsGOTGT1455-QTBDE 5.7" diagonal [320 240 dots], TFT color (65536colors), built-in battery and Ethernet interfaceGT1455-QTBD 5.7" diagonal [320 240 dots], TFT color (65536colors), built-in batteryGT1450-QMBDE 5.7" diagonal [320 240 dots], TFT monochrome(black/white), built-in battery and Ethernet interfaceGT1450-QMBD 5.7" diagonal [320 240 dots], TFT monochrome(black/white), built-in batteryGT1450-QLBDE 5.7" diagonal [320 240 dots], STN monochrome(black/white), built-in battery and Ethernet interfaceGT1450-QLBD 5.7" diagonal [320 240 dots], STN monochrome(black/white), built-in batteryGT1455-QTBD(E), GT1450-QMBD(E)GT1450-QLBD(E)GT14 General DescriptionThis manual describes the part names, dimensions, mounting, and specificationsof the product. Before use, read this manual and manuals of relevant productsfully to acquire proficiency in handling and operating the product. Make sure tolearn all the product information, safety information, and precautions.And, store this manual in a safe place so that you can take it out and read itwhenever necessary. Always forward it to the end user.RegistrationEthernet is a trademark of Xerox Corporation in the United States. The companyname and the product name to be described in this manual are the registeredtrademarks or trademarks of each company.Effective April 2018Specifications are subject to change without notice. 2011 MITSUBISHI ELECTRIC CORPORATIONManual Number JY997D43901HDate April 2018 |
Related manuals for Mitsubishi Electric Got1000 GT1450-QLBD
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved