Mitsubishi Electric EMU-CT100 Instruction Manual
CURRENT SENSORMODEL EMU-CT50, EMU-CT100, EMU-CT250INSTRUCTION MANUAL1 Safety Precautions1.1 Precautions concerning working environment and conditionsDo not use the unit in any of the following places. Doing so may cause malfunctions or a reduction in service life.× Places where the ambient temperature exceeds the working temperaturerange(−5°C to 55°C).× Places where the humidity exceeds the humidity range (5% to 95%RH) or wherecondensation occurs.× Places with a lot of dust, corrosive gas, salt or oily smoke.× Places where the unit may be exposed to rain or drops of water.× Places where metal pieces or inductive substances are laying around.× Places where the daily average temperature exceeds 35°C.× Places with a lot of vibration or impacts.×Places exposed to direct sunlight.×Places where the out of the cabinet.×Places with strong electromagnetic field or noise.×Place where the altitude exceeds 2000m.1.2 Precautions concerning preparations before using the equipment・Use the unit in the specified usage environment and conditions.・Check the current and voltage ratings of the equipment.1.3 Precautions concerning installation and connectionRead thismanualcarefully, and use this instrumentproperly.●Read this manualthoroughly before using the equipment forproper handling.●This manual should beretained for the future reference.●Be sure that the manual isdeliveredto the end users.1.4 Precautions concerning maintenance・Protect the unit from a power failure. Failure to do so can cause unit failures, fires, or electric shocks.・Wipe off the surface dirt with tender cloth. Don’t let chemical cloths touch it for a long time, and do not wipe it with benzine or thinner.1.5 Precautions concerning inspection・Perform the check in the state that does not turn on electricity by all means. Check out the following.a) Does not this product have the damage? b) Are not there an abnormal sound, bad-smelling fever?c) Are not there installation, the slack of the screw?1.6 Precautions concerning storage When storing the unit, turn off power, disconnect cables and wires, and put them in vinyl bags or the like. When storing the unit for a long time, avoid keeping it in the places shown below.× Places where the ambient temperature is out of the range from −10°C to 60°C. × Places where the daily average temperature exceeds 35°C.× Places where the humidity exceeds the humidity range (5% to 95%RH) . × Places with a lot of vibration or impact.× Places where metallic particles or inductive substances are laying around. × Places with a lot of dust, corrosive gas, salt or oily smoke.CautionCaution× Places where the unit is exposed directly to rain, water droplets.1.7 Precautions concerning disposalDispose this product appropriately in accordance with the national or community rule.Perform installation, disassembly, the wiring work after intercepting a power supply by all means. Theremight be the damage of anelectricshockortheproduct.( )Do not install around non-insulated dangerous electric shock conductors that can cause electric shock,electric burn or arc flash. ( )・・Danger2 Installation●Installation1)Open the moving core as shown Figure 1. Slowly lift the moving core locking claws on both sides of the moving core to open and remove them from thestoppers. Before inserting the cable, check the symbols K and L to fit the current sensor in the correct direction. (The direction from the power supply side to theload side is indicated with →.)(Figure 3)2) After checking that the core parting faces are free from dirt, close the moving core. Push up the moving core until the stoppers are securely locked. (When themoving core securing claws on both sides catch on the stoppers, you hear two clicks.)(Figure 2)3) Pass the tying bands into the current sensor locking holes to secure the sensor with the cable.(Figure 3)*For the details, see the manual for combination measurement unit.*Applicable wire size in the table of specification is the normal sectional areas of 600V vinyl-coated cable.These values are the standard nominal sectionalareas.These electric wires may not pass through the sensor owing to the error of the outer diameters of vinyl insulators finished by manufacturers ordeformation (bending) of the wires.Check the wire on site.●Connection・For the details,・ see the manual for the combination measurement unit.3 SpecificationLocking hole(3×2)MovingcorePrimary Cable(Figure 1)Moving coreparting facePrimaryCable(Figure 2)Moving corelocking clawStopperMoving corelocking clawDirectionof current(Figure 3)*Buy the tying bands.Directionof currentProtectivecoverTying bndK side setLINE side(LINE side) (LOAD side) |
Related manuals for Mitsubishi Electric EMU-CT100
Mitsubishi Electric k-con KS9-BS1-A Instruction Manual
Mitsubishi Electric PZ-70CSB-E Installation And Instruction Manual
Mitsubishi Electric DPLS2 Installation Manual
Mitsubishi Electric PAC-AK53BC Installation Manual
Mitsubishi Electric PAC-SE41TS-E Installation Manual
Mitsubishi Electric PAC-SH91MK-E Installation Manual
Mitsubishi Electric Lossnay PZ-70CSW-E Installation And Instruction Manual
Mitsubishi Electric R410A Manual
Mitsubishi Electric VS20M-11F310 Connection Manual
Mitsubishi Electric MELSENSOR VS20 Connection Manual
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved