Mitsubishi Electric AJ65SBTB1-16D User Manual
SAFETY PRECAUTIONS(Read these precautions before using this product.)Before using this product, please read this manual carefully and pay fullattention to safety to handle the product correctly.The precautions given in this manual are concerned with this product only.For the safety precautions of the programmable controller system, refer to theuser's manual for the CPU module used.In this manual, the safety precautions are classified into two levels:" WARNING" and " CAUTION".Under some circumstances, failure to observe the precautions given under" CAUTION" may lead to serious consequences.Observe the precautions of both levels because they are important forpersonal and system safety.Make sure that the end users read this manual and then keep the manual in asafe place for future reference.(2403) MEE[Design Precautions][Installation Precautions][Wiring Precautions]WARNING In the case of a communication failure in the network, the status of the error stationwill be as follows:(1) All inputs from remote I/O stations are turned off.(2) All outputs from remote I/O stations are turned off.Check the communication status information and configure an interlock circuit inthe sequence program to ensure that the entire system will operate safely.Incorrect output or malfunction due to a communication failure may result in anaccident. Outputs may remain on or off due to a failure of a remote I/O module. Configure anexternal circuit for monitoring output signals that could cause a serious accident.CAUTION Use the module in an environment that meets the general specifications in theuser's manual for the CPU module used. Failure to do so may result in electricshock, fire, malfunction, or damage to or deterioration of the product. Do not install the control lines or communication cables together with the maincircuit lines or power cables. Keep a distance of 100mm (3.94 inches) or morebetween them. Failure to do so may result in malfunction due to noise.CAUTION Do not directly touch any conductive parts of the module. Doing so can causemalfunction or failure of the module. Securely fix the module with a DIN rail or mounting screws. Tighten the screwswithin the specified torque range. Undertightening can cause drop of the screw,short circuit or malfunction. Overtightening can damage the screw and/or module,resulting in drop, short circuit, or malfunction. Securely connect the cable connectors. Poor contact may cause malfunction.WARNING Shut off the external power supply for the system in all phases before wiring.Failure to do so may result in electric shock or cause the module to fail ormalfunction.CAUTION Ground the FG terminal to the protective ground conductor dedicated to theprogrammable controller. Failure to do so may result in electric shock ormalfunction. Tighten any unused terminal screws within the specified torque range (0.42 to0.50N•m). Failure to do so may cause a short circuit due to contact with asolderless terminal. Use applicable solderless terminals and tighten them within the specified torquerange. If any spade solderless terminal is used, it may be disconnected when theterminal screw comes loose, resulting in failure. Check the rated voltage and terminal layout before wiring to the module, andconnect the cables correctly. Connecting a power supply with a different voltagerating or incorrect wiring may cause a fire or failure. Tighten the terminal screw within the specified torque range. Undertightening cancause short circuit, fire, or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or malfunction. Prevent foreign matter such as dust or wire chips from entering the module.Such foreign matter can cause a fire, failure, or malfunction. Place the cables in a duct or clamp them. If not, dangling cable may swing orinadvertently be pulled, resulting in damage to the module or cables or malfunctiondue to poor contact.WARNINGCAUTIONIndicates that incorrect handling may cause hazardousconditions, resulting in death or severe injury.Indicates that incorrect handling may cause hazardousconditions, resulting in minor or moderate injury orproperty damage.[Startup and Maintenance Precautions][Disposal Precautions]●CONDITIONS OF USE FOR THE PRODUCT●CAUTION Do not install the control lines or communication cables together with the maincircuit lines or power cables. Failure to do so may result in malfunction due tonoise. When an overcurrent caused by an error of an external device or a failure of theprogrammable controller flows for a long time, it may cause smoke and fire.To prevent this, configure an external safety circuit, such as a fuse. When disconnecting the cable from the module, do not pull the cable by the cablepart. For the cable with connector, hold the connector part of the cable. For thecable connected to the terminal block, loosen the terminal screw. Pulling the cableconnected to the module may result in malfunction or damage to the module orcable.WARNING Do not touch any terminal while power is on. Doing so will cause electric shock ormalfunction. Shut off the external power supply for the system in all phases before cleaning themodule or retightening the terminal screws or module mounting screws. Failure todo so may result in electric shock.CAUTION Do not disassemble or modify the modules. Doing so may cause failure,malfunction, injury, or a fire. Do not drop or apply strong shock to the module. Doing so may damage themodule. Shut off the external power supply for the system in all phases before mounting orremoving a module. Failure to do so may cause the module to fail or malfunction. After the first use of the product, do not mount/remove the terminal block to/fromthe module more than 50 times (IEC 61131-2 compliant). Before handling the module, touch a conducting object such as a grounded metalto discharge the static electricity from the human body. Failure to discharge thestatic electricity may cause the module to fail or malfunction. For details on thesafety precautions concerning the electrostatic discharge, check the standards ofIEC 61340-5-1 and IEC 61340-5-2.CAUTION When disposing of this product, treat it as industrial waste.(1) MELSEC programmable controller ("the PRODUCT") shall be used in conditions;i) where any problem, fault or failure occurring in the PRODUCT, if any, shall notlead to any major or serious accident; andii) where the backup and fail-safe function are systematically or automaticallyprovided outside of the PRODUCT for the case of any problem, fault or failureoccurring in the PRODUCT.(2) The PRODUCT has been designed and manufactured for the purpose of beingused in general industries.MITSUBISHI ELECTRIC SHALL HAVE NO RESPONSIBILITY OR LIABILITY(INCLUDING, BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY ORLIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCTLIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS ORDAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATEDOR USED IN APPLICATION NOT INTENDED OR EXCLUDED BYINSTRUCTIONS, PRECAUTIONS, OR WARNING CONTAINED IN MITSUBISHIELECTRIC USER'S, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICALBULLETINS AND GUIDELINES FOR the PRODUCT.("Prohibited Application")Prohibited Applications include, but not limited to, the use of the PRODUCT in;Nuclear Power Plants and any other power plants operated by Powercompanies, and/or any other cases in which the public could be affected if anyproblem or fault occurs in the PRODUCT.Railway companies or Public service purposes, and/or any other cases inwhich establishment of a special quality assurance system is required by thePurchaser or End User.Aircraft or Aerospace, Medical applications, Train equipment, transportequipment such as Elevator and Escalator, Incineration and Fuel devices,Vehicles, Manned transportation, Equipment for Recreation and Amusement,and Safety devices, handling of Nuclear or Hazardous Materials or Chemicals,Mining and Drilling, and/or other applications where there is a significant risk ofinjury to the public or property.Notwithstanding the above restrictions, Mitsubishi Electric may in its solediscretion, authorize use of the PRODUCT in one or more of the ProhibitedApplications, provided that the usage of the PRODUCT is limited only for thespecific applications agreed to by Mitsubishi Electric and provided further that nospecial quality assurance or fail-safe, redundant or other safety features whichexceed the general specifications of the PRODUCTs are required. For details,please contact the Mitsubishi Electric representative in your region.(3) Mitsubishi Electric shall have no responsibility or liability for any problemsinvolving programmable controller trouble and system trouble caused by DoSattacks, unauthorized access, computer viruses, and other cyberattacks.൘䀖᪨⁑ඇѻࡽˈᗵ享ݸ᧕䀖ᐢ᧕ൠⲴ䠁ㅹሬ⭥փˈ䟺᭮ᦹӪփᡰᩪᑖⲴ䶉⭥DŽྲ᷌н䟺᭮ᦹ䶉⭥ˈਟ㜭ሬ㠤⁑ඇ᭵䳌ᡆ䈟ࣘDŽޣҾ䟺᭮䶉⭥ޣⲴᆹޘ⌘һ亩Ⲵ䈖㓶ᇩˈ䈧⺞䇔,(&৺,(&Ⲵḷ߶DŽ1. Part Names and Settings*1 A unique station number should be set.2. Operating Ambient TemperatureUse the module in the ambient temperatures of 0 to 55°C.(This product has been assessed as "Surrounding air temperature rating"when it is UL-certified.)No. Item DescriptionOperationstatus indicatorLEDLED name DetailsPW On: Power being suppliedOff: No power suppliedL RUN On: Normal communicationOff: No communication (timeout error)L ERR.On: Communication errorFlashing regularly:The station number or transmission speedswitch setting is changed while power is on.Flashing irregularly:The terminating resistor setting is incorrect.;The module or CC-Link dedicated cable isaffected by noise.Off: Normal communicationX0 to XF On: Input ONOff: Input OFFTransmissionspeed settingswitchSettingSetting switchstatus Transmissionspeed4 2 10 OFF OFF OFF 156kbps1 OFF OFF ON 625kbps2 OFF ON OFF 2.5Mbps3 OFF ON ON 5.0Mbps4 ON OFF OFF 10MbpsSet the transmission speed within the above range.Station numbersetting switchSelect "10", "20", or "40" for the tens place.Select "1", "2", "4", or "8" for the ones place.Set the station number within the range of 1 to 64. *1(Example)Setting the station number to 32:StationnumberTens place Ones place40 20 10 8 4 2 132 OFF ON ON OFF OFF ON OFFTerminal block Terminal block for module power supply, transmission, andI/O signalsDIN rail hook When mounting the module to a DIN rail, push in the DIN railhook until it clicks.AJ65SBTB1-16D CC-Link System Compact Type Remote I/O Module User's ManualIB No. IB-68957-QModel AJ65SBTB1-16D-U |
Related manuals for Mitsubishi Electric AJ65SBTB1-16D
Mitsubishi Electric AJ65SBTB1-32T User Manual
Mitsubishi Electric AJ65SBTB1-32D1 User Manual
Mitsubishi Electric AJ65SBTB1-32T-U User Manual
Mitsubishi Electric AJ65SBTB2N-16A User Manual
Mitsubishi Electric AJ65SBTB1-32T1 User Manual
Mitsubishi Electric AJ65VBTS3-16D User Manual
Mitsubishi Electric AJ65VBTCE3-16D User Manual
Mitsubishi Electric AJ65SBTC1-32DT User Manual
Mitsubishi Electric AJ65SBTC1-32T1 User Manual
Mitsubishi Electric AJ65SBT2B-64RD3 User Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved