Mitsubishi Electric 2F-YZ581 Manual
■Wiring diagramThe place where the short-connector should be inserted depends on theencoder type.By referring to the following figures, insert the short-connectoraccording to the encoder type.For the RH-FRH and RV-FR series, an externalpower supply needs to be connected to the controller.Power can also besupplied from the 5V output section of the encoder distribution unit instead ofusing an external power supply.For details on wiring of the robot controllersection, refer to the Tracking Function Manual.Item Specification RemarksModel name 2F-YZ581Supported robot RH-SDH series / RV-SD series, RH-SQH series / RV-SQ seriesRV-F series / RH-FH seriesRH-FRH series / RV-FR seriesCR750/CR751 series controllerCRn-700 series controllerCR800 series controllerEncoder input 2 channel Only 1 channel availableSupported encoder Output type: Open collector output/Voltage output/Line driver outputResolution(pulse/rotation) : max 2000(non-compliant 4000 , 8000)Operation checked encoder: E6B2-CWZ1X-2000 (omron)Supported encoder could be changedwith the shorting connector. Refer towiring diagram for detail.Cable Type:Shielded twisted-pair cableConductor size::Refer to Wiring directionsCable length:Refer to Communication specificationsOutputchannelsFor robot controller 4 channels (in the case two encoders are connected)8 channels (in the case one encoder is connected)Enable to increase the number ofoutput channel by cascade.For cascading 1 channelOutput type Line driver outputPowersupplyInput voltage 24Vdc(±10%)Power consumption 500mA Depends on the encoder type.Encoder supply Voltage: 5Vdc, Current: 160mA, 2 channelProtection specification IP20Ambient environment General environment Without inflammable gas or corrosivegasAmbient air temperature 0℃~40℃Ambient humidity 45~85% Without dew dropsMass Approx. 600 g■SpecificationsMitsubishi Electric Industrial RobotEncoder Distribution Unit ManualCR750/CR751 series controllerCRn-700 series controllerCR800 series controller■IntroductionEncoder distribution unit 2F-YZ581 is used when one rotary encoder is connected to multiple robot controllers whenthe tracking function is used. The details of 2F-YZ581 are described in this sheet. For details of the tracking function,please refer to the “Tracking function manual” attached to the robot .The CR800 series indicates the CR800 and CR860 controllers.PrecautionsDo not use the unit in excess of rated voltage or it could suffer damage.Wire the power supply correctly or it could suffer damage.Wire the cable in the shortest path in order to avoid noise.Do not short or ground the output signal, or it can be burst or damaged.Make sure the unit is turned off when wiring, inserting or pulling out of the connector, orit could suffer damage.Do not drop this unit.Place this unit on an even surface, free from vibration.ENC1IN ENC1OUT1Encoder distribution unitEncoder 124V(Power supply)ENC1CSCEncoder distribution unit24V(Power supply)Encoder 2Encoder 1 cascadeEncoder 2 cascadeEncoder 1 distributionEncoder 2 distributionENC1OUT2ENC1OUT3ENC1OUT4ENC2OUT1ENC2OUT2ENC2OUT3ENC2OUT4ENC2CSCDC24ENC2INRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerENC1IN ENC1OUT1ENC1CSCEncoder 2 distributionENC1OUT2ENC1OUT3ENC1OUT4ENC2OUT1ENC2OUT2ENC2OUT3ENC2OUT4ENC2CSCDC24ENC2INEncoder 1 distributionNo. Encoder type Short-connector point1 Line driver output MODE12 Open collector outputVoltage outputMODE2■Configuration diagramThe connection method differs according to the number of encoders and robot controllers. Connect instruments byreferring to the following examples of configurations. Please have power supply and encoders ready.Configuration example 1Encoder : 1 unitRobot controller : 4 unitsEncoder distribution unit : 1 unit*Please do not wire the unused terminal blocks.ENC1IN ENC1OUT1Encoder distribution unitEncoder 124V(Power supply)ENC1CSCEncoder 1 cascadeEncoder 1 distributionENC1OUT2ENC1OUT3ENC1OUT4ENC2OUT1ENC2OUT2ENC2OUT3ENC2OUT4ENC2CSCDC24ENC2INRobot controllerRobot controllerRobot controllerRobot controllerEncoder distributionConfiguration example 3Encoder : 2 unitsRobot controller : 4 unitsEncoder distribution unit : 1 unitENC1IN ENC1OUT1Encoder distribution unitEncoder 124V(Power supply)ENC1CSCEncoder 1 cascadeEncoder 1 distributionEncoder 2 distributionENC1OUT2ENC1OUT3ENC1OUT4ENC2OUT1ENC2OUT2ENC2OUT3ENC2OUT4ENC2CSCDC24ENC2INRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerRobot controllerConfiguration example 2Encoder : 1 unit (Line driver output encoder only)Robot controller : 8 unitsEncoder distribution unit : 1 unit*Please do not wire the unused terminal blocks.Connection betweenENC1CSC and ENC2INis needed*Please do not wire the unused terminal blocks.Connection betweenEncoder distribution unitsis needed.Connection between Encoder distribution units is needed toconnect the encoder to more than five robot controllers. Refer tothe wiring diagram and the enclosed area below .Connection for cascadeBFP-A3300-CBFP-A3300-CEncoder type: Line driver output (MODE1)Voltage outputOpen collector outputEncoder type: Open collector output / Voltage output (MODE2)Power supply 0V+24VABABDC24ENC1IN /ENC2INZZENC1OUT1-ENC1OUT4 /ENC2OUT1-ENC2OUT4ABABZZENC1CSC / ENC2CSCABABZZGNDGNDGNDGNDV5GNDGNDSLDRobot controllerLine driver outputMODE1MODE2Short-connectorEncoder distribution unitEncoder distribution unitENC1IN/ENC2INEncoder1 /Encoder2ABBZZV50V0V0VAABABZZ0V0VABABZZ0V0V-+-+Power supply 0V24VABDC24ENC1IN /ENC2INZENC1OUT1-ENC1OUT4 /ENC2OUT1-ENC2OUT4ABABZZENC1CSC / ENC2CSCABABZZGNDGNDGNDGNDV5GNDGNDSLDRobot controllerMODE1MODE2Short-connectorEncoder distribution unitEncoder distribution unitENC1IN/ENC2INEncoder1 / Encoder2ABABZZ0V0VABABZZ0V0VABBZZV50V0V0VAConnection with the robot controller(for the RH-FRH and RV-FR series)Connection with the robot controller(for the RH-FRH and RV-FR series) |
Related manuals for Mitsubishi Electric 2F-YZ581
Mitsubishi Electric MELFA Hardware Manual
Mitsubishi Electric MELFA BFP-A3614 Manual
Mitsubishi Electric MELFA CR860 Series Manual
Mitsubishi Electric R56TB Instruction Manual
Mitsubishi Electric CR800-D Series User Manual
Mitsubishi Electric RH-1FRHR Instruction Manual
Mitsubishi Electric melfa RV-5AS Instruction Manual
Mitsubishi Electric MELFA CR800-D Series User Manual
Mitsubishi Electric MELFA FR CR800 Series User Manual
Mitsubishi Electric 4F-FS001-W200 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved