13Installation and Service ManualOPERATIONUNIT INSPECTIONThoroughly inspect the unit upon delivery. Immediately report any damage that occurred during transportation tothe delivery carrier. Request a written inspection report from a claims inspector to document any necessary claim.ICE RECOMENDED FOR DISPENSINGMII dispensers are designed to dispense hard, cube ice up to one-inch square. The ice shapes and sizes listed aboveare recommended for dispensing. Warm “Super Cooled” Ice Before Dispensing “Super Cooled” ice is not recom-mended for dispensing. “Super cooled” ice is ice that has been stored in freezers below 32o F. Should it be necessary totemporarily use “super cooled” ice, allow the ice to warm at room temperature for 25 to 30 minutes before placing the icein the dispenser.Dispensing compressed flake “nugget” ice in Servend dispensers takes special handling. Most dispensers requirespecial bin components and a universal ice management kit. Contact MBE regarding details for your installation.ICE STORAGE AND DISPENSINGAs the customer presses the rocking chute, the arm at the top left rear of the chute pushes upward on the door lock. Thedoor opens until it contacts the stops in the mounting brackets. The plastic arm on the ice chute also activates the leverof the ice dispensing switch. When activated, the micro switch starts the gear motor. The gear motor turns the paddlewheel and agitator arm.The paddlewheel carries ice. Periodic agitation is optional on the MII-150 and MII-175 and is standard on the MII-200,MII-250, MII-302 and MII-402. During periodic agitation, the paddle wheel and agitator turn for approximately threeseconds every three and one half-hours. The door lock prevents ice from being dispensed during the agitation cycle.BEVERAGE VALVESPost-mix beverage valves are designed to precisely meter the flow of both water and syrup to obtain the proper mixingratio. The syrup and soda water components of the post-mix beverage are mixed as they leave the beverage valve.LEGSLegs are optional equipment with most MBE dispensers. Standard legs are four-inch (10.2 cm) tall stainless steel legs.MII 302 and MII 402 cannot be placed on legs. When installing legs on a MII Series dispenser, leg braces should beused. These are metal braces fitting side to side under the dispenser that reinforce the leg attachment area. It isrecommended if an icemaker is installed on top of the dispenser, legs should not be installed.115V/220V NON ADJUSTABLE AGITATION TIMERThe agitation timer on this unit is equipped with test pins. This allows you to test the timer by removing the jumperbetween the two pins. When the jumper is removed the timer will cycle every 55 seconds if it is operating correctly. If thetimer is wired correctly and does not cycle approximately every 55 seconds when the jumper is removed, replacementof the timer may be necessary. Make sure to replace the jumper pins when finished.NOTES: This timer is re-settable, timed agitation every 3.5 hours from last dispense on power supply broken. Neveroperate in normal mode without test pins in place, damage could occur.