5 ENGLISHOverloaded:The tool is operated in a manner that causes it to drawan abnormally high current.In this situation, turn the tool off and stop the applicationthat caused the tool to become overloaded. Then turnthe tool on to restart.If the tool does not start, the battery is overheated. Inthis situation, let the battery cool before turning the toolon again.Low battery voltage:The remaining battery capacity is too low and the toolwill not operate. If you turn the tool on, the motor runsagain but stops soon. In this situation, remove andrecharge the battery.Indicating the remaining batterycapacityOnly for battery cartridges with "B" at the end of themodel number12► 1. Indicator lamps 2. Check buttonPress the check button on the battery cartridge to indi-cate the remaining battery capacity. The indicator lampslight up for few seconds.Indicator lamps RemainingcapacityLighted Off75% to 100%50% to 75%25% to 50%0% to 25%NOTE: Depending on the conditions of use and theambient temperature, the indication may differ slightlyfrom the actual capacity.Switch action1► 1. Switch triggerCAUTION: Before installing the battery car-tridge into the tool, always check to see that theswitch trigger actuates properly and returns tothe "OFF" position when released.To start the tool, simply pull the switch trigger. Toolspeed is increased by increasing pressure on the switchtrigger. Release the switch trigger to stop.NOTE: The tool automatically stops if you keep pull-ing the switch trigger for about 6 minutes.Lighting up the front lampCAUTION: Do not look in the light or see thesource of light directly.1► 1. Lamp