Magnum Energy ME-PT1 Instruction Sheet
Also see for ME-PT1: Instruction sheetInstruction sheet
ME-PT1 Instruction Sheet4 © 2014 Magnum Energy, Inc.Figure 4, ME-PT1 to ME-AGS-S Installation12-voltDC supplyfuse12-voltDC supplyfuseExternalMaintain SwitchExternalMomentary SwitchOne time push (orclose): Gen runs forduration of RUN TIMEHOURS period.Coleman Air Conditioner Zone Control BoxONOFFON: Gen continuesto run.OFF: Gen stopsonce current RUNTIME HOURS cyclehas been satisfied.optionsGEN connectionprovides +12VDCfrom Zone ControlBox when gen needsto start.GENconnectionGREEN (GND)WHITE (L2)BLACK (L1)ZONE CONTROL BOX115VAC IN9-PIN PLUG TOUPPER UNITFRE EZE ROOM HE ATSHEDCOOLSHEDTO USE WITHLOAD SHEDDEVICE REMOVEJUMPER ANDCONNECT TON.C. CONTATCT ROOMSENSORFREEZE SENSORPT1-AGSPhone Splitter(6-conductor)ME-AGS-SRemote Switch(with Temp Sensor opened)All grounds must bebonded together toensure the ME-PT1works correctlyME-PT1AUTO GEN STA RTENABLEOFFTESTME-PT1 Instruction SheetPart Number: 64-0025 Rev B 1IntroductionThe ME-PT1 (pigtail one-wire) adapter connects to Magnum’s Auto GeneratorStart (ME-AGS) controller to allow the connected generator to start when anexternal +12-volt DC supply is applied. This is useful for applications in whichthere is a need to automatically turn the generator on/off externally, eitherthrough a manually controlled switch or from an automatically controlledswitching device.When +12-volts is supplied to this pigtail wire it causes the AGS controller tostart and run the connected generator.Info: The high temperature start feature on the AGS is not availablewhen using the ME-PT1. However, the low battery voltage startfeature is still available.Installation/Setup – ME-AGS-N (Network Version)The following pertains to the ME-PT1 when connected to the ME-AGS-N.Info: Refer to the ME-AGS-N Owner’s Manual (64-0039) forinstallation, setup, and operation of the ME-AGS-N; and to the ME-RC (64-0003) or ME-ARC owner’s manuals (64-0030) for informationon selecting/adjusting settings.InstallationTo install the ME-PT1, refer to Figure 1 and the steps below:1. Connect the red wire on the ME-PT1 adapter to a +12-volt DC externalswitching device (i.e., switch).2. Plug the ME-PT1 adapter into the REMOTE (purple) port on the ME-AGS-N.Info: The remote temperature sensor that comes with theME-AGS-N (normally plugged into the AGS’s REMOTE port) is notused when a ME-PT1 is connected.SetupWhen using the ME-PT1 with the ME-AGS-N, configure the ME-RC (or ME-ARC) to allow the ME-AGS-N to accept the external input from the ME-PT1.• Find the temperature start setting—depending on your remote: ME-RC(under AGS/04 Start Temp F menu), or ME-ARC (under SETUP/04E GenRun Temp/Start menu). Then, select the Start=Ext Input setting.ME-PT1 to ME-AGS-N OperationThe type of external switch (i.e., “momentary” or “maintain”) connected tothe ME-PT1 adapter determines how long the generator can run.ME-RCA. Using a momentary type switch: Pressing the switch causes the generatorto run for the duration of a full run time cycle (as set in the AGS/03 Run TimeHour menu), and then stop.B. Using a maintain type switch: If the switch is set to ON, the generatorcontinues to run until the switch is set to OFF. Once the switch is set to OFF,the generator will continue to run for the remaining duration of the currentrun time cycle (as set in the AGS/03 Run Time Hour menu), and then stop. |
Related manuals for Magnum Energy ME-PT1
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved