15• A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. The intercon-nect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, CO,Smoke/ CO Combination, heat, etc.). With 18 alarms interconnected, it is still possible to interconnect up to a total of6 remote signaling devices and / or relay modules.• Maximum distance between wireless interconnect models is greater than 300 feet in open air.9.1 Setting Up a Wireless Alarm NetworkCreating an interconnected wireless alarm network is a simple process, with intelligent “self-enrollment” features, anduser-friendly voice prompts.A. reMoVe All deVICeS froM theIr PACkAgIngb. PoWer UP All deVICeS• Locate the red wheel on the back of the device. Turn the red wheel to the “ON” position on ALL devices using thewhite tool included with the Quick Start Guide.• Once powered, the light rings will glow red and voice message willannounce, “Ready to connect. Follow Quick Start instructions.”note: If no further steps are taken within 15 minutes of initial power up, avoice prompt, “No devices found, not connected” will be heard once, and the wireless function will turn off. The unitwill then perform as a stand alone alarm. See Section 9.3 for re-activating wireless.Figure 9.1-BONACTIVATIONTOOL