2SPECIFICATIONSExternal fire dimensions (mm) PerformanceModel Model No. Width Depth Height AverageemissionsAverageefficiency ECAN NO *Cardrona KWF295-6960 535 490 648 0.80g/kg 69% 165498Oxford KWF295-6961 535 490 648 0.80g/kg 69% 165500Benmore KWF295-6962 535 490 648 0.80g/kg 69% 165499Haast KWF295-6950 575 560 730 0.98g/kg 66% 144660Murchison KWF295-6952 575 560 730 0.98g/kg 66% 144662Aspiring KWF295-6951 575 560 730 0.98g/kg 66% 144661Ruapehu KWF295-6965 760 588 718 0.54g/kg 66% 191312* ECAN NO = Environment Canterbury authorisation number. TABLE 1NNMinimum Installation Clearances (with flue shield) mm Hearth Clearances (mm)Model Model No. A B C* D E F G H J K L M NCardrona KWF295-6960 135 350 300 130 120 270 610 395 795 855 1140 585 1000Oxford KWF295-6961 135 350 300 130 120 270 610 395 795 855 1140 585 1000Benmore KWF295-6962 135 350 300 130 120 270 610 395 795 855 1140 585 1000Haast KWF295-6950 160 360 300 130 190 320 645 500 835 960 1340 640 1160Murchison KWF295-6952 160 360 300 130 190 320 645 500 835 960 1340 640 1160Aspiring KWF295-6951 160 360 300 130 190 320 645 500 835 960 1340 640 1160Ruapehu KWF295-6965 150 200 300 100 170 315 580 540 960 913 1375 640 1180* Fuel loading opening to end of floor protector.Wall Clearances Corner Clearances FIG. 1TABLE 2MINIMUM INSTALLATION CLEARANCESDescription Model No.Standard - 4.2m KWF298-7005 Tested to AS/NZS 2918, Appendix F, ARS report No;02/649Energy Saver - 4.2m KWF298-7006 Tested to AS/NZS 2918, Appendix F, ARS report No;02/649Sloping Ceiling - 4.2m KWF298-7354 Tested to AS/NZS 2918, Appendix F, ARS report No;14/2718RECOMMENDED FLUE KITS FOR KENT FREE STANDING WOOD FIRES