16 English 5.906-494.0 Rev. 01 (04/11) Loosen both hollow screws at the same time to re-move the overflow casing in order not to damagethe O-rings.1 Adjustment screw, high pressure2 Lock nut, adjustment screw, high pressure3 Spindle, pressure and quantity regulation4 Adjustment screw, low pressure5 Lock nut, adjustment screw, low pressure6 Housing, overflow valvePreparation Fasten the test manometer to the high-pressureconnection. Connect the high-pressure hose with the servopress hand spray gun to the test manometer.Setting the maximum working pressure: Rotate the servo press to the "MIN" position, openthe hand spray gun and let the device run. Turn in the rotary handle of the pressure andquantity regulation until it stops (MAX value). Pull off the rotary handle. Loosen the locknut for high pressure. Turn the adjustment screw high pressure so thatthe pressure display on the test manometerequals the maximum working pressure in theChapter "Specifications". Secure the adjustment screw for high pressure bytightening the locknut. Seal the adjustment screw for high pressure andthe lock nut with locking paint.Setting the minimum working pressure: Install thenew high pressure nozzle. Rotate the servo press to the "MAX" position,open the hand spray gun and let the device run. Pull off the rotary handle. Loosen the locknut for low pressure. Turn the adjustment screw low pressure and thespindle for pressure/quantity regulation at thesame time, so that the pressure display on the testmanometer equals the minimum working pressurein the Chapter "Specifications". Secure the adjustment screw for low pressure bytightening the locknut. Seal the adjustment screw for high pressure andthe lock nut with locking paint.5.4.5 Regulate the working pressure by means ofthe rotary know on the gun