Operating Instructions HD 10/25 S VEX English12Technical SpecificationsHD 10/25 S VEXMains connectionVoltage V 380 220Type of current Hz 3~50 3~60Connected load kW 7.7 7.5Supply fuse (delayed-action, char. C) A 16 25Max. tolerable mains impedance Ω (0.145 + j0.090)Extension cable 10 m mm 2 2.5 2.5Extension cable 30 m mm 2 4 –Water connectionSupply temperature max. °C 60Supply volume min. l/h (l/min) 1200 (20)Supply hose – minimum length m 7.5Supply hose – minimum diameter inches 3/4Suction height from an open container 20 °C m 0.5Supply pressure max. MPa (bar) 1 (10)Performance dataOperating pressure MPa (bar) 3–19 (30–190)Max. operating overpressure (safety valve) MPa (bar) 20.9 (209)Flow rate l/h (l/min) 500–1038 (8.3–17.3)Detergent intake l/h (l/min) 0–80 (0–1.3)Recoil force of the handgun N 62Sound emissionSound pressure level(EN 60704-1)dB (A) 72Guaranteed sound pressure level(2000/14/EC)dB (A) 87Vibrations of unit / total of vibration (ISO 5349)Handheld gun m/s2 2.2Spray lance m/s 2 2.0DimensionsLength mm 560Width mm 500Height mm 1090Weight without accessories kg 62Reservoir capacity, detergent l 6Oil quantity, pump l 1.2Oil type, pump SAE 90