70Operations (Step 6 Operations with a Web Browser)6-4 Settings with a Web Browser (4. Alarm Settings)Alarm Setting Window:http://******/alarm-e.html (****** represents the URL of VN-C11.)This section describes the setting of actions of VN-C11 when an alarm signal has been received.Item EffectAlarm In Specifies the action when an alarm signal has been received.Alarm 1 and 2 Specifies the action when an alarm signal has been input to[Alarm 1] and/or [Alarm 2].On/Off Select [On] if the alarm terminals [Alarm 1] and/or [Alarm 2]are to be used. If not to be used, select [Off].Alarm Out If [On] is selected here, alarm signals are output to the[ALARM OUTPUT] terminal located on the rear panel.Relay Alarm Sets the relay alarm function, which is activated when twoalarms are successively received within a certain period oftime.On/Off Select whether to enable or disable the relay alarm function.Relay Alarm Setting Sets the sequence and interval of alarm input.Alarm Out If [On] is selected here, alarm signals are output to the[ALARM OUTPUT] terminal located on the rear panel.Alarm OutOn/Off Select [On] for alarm signals to be output to the [ALARMOUTPUT] terminal located on the rear panel.Momentum Sets the duration for sending alarm output signals.Value Sets whether to output high or low signals for alarm output.Power on Init If [Yes] is selected, the alarm signal, which was set uponpower connection, is output once.Caution• Perform the output setting appropriately according to the equipment to which signals aresent.• When the alarm setting is complete, check whether the alarm functions are working prop-erly.Click [Apply] to update the settings.