OperationTM/TMC/RM/RMC-2030GE- 61 -10.5.6 PWC PIV ModeThe PWC PIV is based on PIV Fixed Exposure. In this mode, the first time exposure is controlled by thepulse width of the external trigger, which is similar to PWC mode. The real exposure time of the firstimage is equal to the pulse width of the external trigger.The maximum trigger frequency in this mode is equal to 1/ (transfer time of two frames + exposuretime of the first image).The minimum active period of the external trigger is 10 pixel clocks (250ns)Figure 60. PWC PIV Timing Table.Table 8. Asynchronous Mode ChartAsyn No Shutter Async Preset and Prog. Shutter PWCaA <1 line <1 line 6 clkaB 9.5 line (n+1) lines + 1024 clk Pulse width + 1024 clkaC 1024 clkAsyn No Shutter Async Preset and Prog. Shutter PW CaA <1 line <1 line 6 clkaB 9.5 line (n+1) lines + 298 clk Pulse width + 48 clkaC 48 clkPIV Fixe Expo PIV PW C UnitpA 6 6pB 70 70pC 200 200 PixelpD 320 320pE 20 20pF 1 1 Frame