BM-500CL / BB-500CL- 7 -5. Pin Assignment5.1. 12-pin Multi-connector (DC-IN/Trigger)Type: HR10A-10R-12PB-01 (Hirose) male.Use the part number HR10A-10P-12S for the cable side*1) XEEN output can be configured with complementary emitter follower circuit or open collectorby internal switch setting. The default is the complementary emitter follower circuit. Seechapter 5.3.3 for details.*2) Factory default is trigger via Camera Link*3) 75 ohm termination can be enabled by SW 800. See Chapter 7.15.2. Digital Output Connector for Camera LinkType: 26-pin MDR connector (3M 10226-1A10PL)Fig.3 26-Pin Camera Link ConnectorPin No In/Out Name Note1,14 Shield GND2(-),15(+) O TxOUT0Data out3(-),16(+) O TxOUT14(-),17(+) O TxOUT25(-),18(+) O TxClk Clock for CL6(-),19(+) O TxOUT3 Data out7(+),20(-) I SerTC (RxD) LVDS Serial Control8(-),21(+) O SerTFG (TxD)9(-),22(+) I CC1 (Trigger) Trigger IN10(+),23(-) N.C11,24 N.C12,25 N.C13,26 Shield GNDPin no. Signal Remarks1 GND2 +12 V DC input3 GND4 Iris video Only for Continuous mode. TR=05 GND6 NC7 NC8 GND9 XEEN out *1)10 Trigger in TI=1 (or Camera Link TI=0). *2)*3) 75 ohm termination11 DC+12V12 GNDFig. 2 Hirose 12-pin connector