IBERITAL DE RECAMBIOS, S.A.2.3.- ELECTRICAL CONNECTIONIMPORTANT: This equipment is to be permanently cord connected.The machine is fitted with heating and other electric elements of either 110V, 220V or 240Vdepending on the version. A circuit breaker, with an adequately rated fuse, must be fitted between theappliance and the mains. The maximum power consumption is indicated on the data plate (17).The green wire must be connected to an efficient grounding installation.220V-240V SINGLE PHASE.The machine can be connected in single phase, in this case the black wire should be joined togetherwith the red wire and then connected to phase. The white wire must be connected to other phase.Green wire to ground.Black Red White Green--///Phase (R)Phase (S)220V-240V THREE PHASE WITHOUT NEUTRAL.The machine can be connected in three phase 220V without neutral, to do this connect the black wireto one of the three phases and the red wire to another of the three phases and then the white wire to theremaining phase. Green wire to ground.Black Red White Green--///Fase (R)Fase (S)Fase (T)MANUAL NEW IBERITAL INGLES Página 26 de 3011/05/2007