VISTA-15P/20P/SIA Installation and Setup Guide7Mounting and Wiring the Control (Continued)Keypad Notes Set device addresses. Refer to the instructions included with the devices and set eachaddress according to the Table of Device Addresses.See data fields *190-*196 in the Programming Guide for details on enabling keypadaddresses, assigning keypad partitions, and selecting keypad sounding options.IMPORTANT: Each keypad must be assigned a unique, predefined address, from 16 to 23.The first keypad is address 16 (default = partition 1, all sounds enabled).TOUCH SCREEN KEYPAD (AUI) NOTES: Use of AUI devices (e.g., 6280, Tuxedo) is independent from standard keypads and doesnot affect the number of standard keypads the system can support. AUI devices must be set for address 1, 2, 5**, or 6** depending on which unit is enabled infield *189. ** VISTA-20P seriesCommunication Device(Long Range Radio)ConnectionsConnect the data in/data out terminals and voltage input terminals of the communicationdevice to the control's keypad connection points.Set the device’s address to “03” following the instructions provided with the device. Use a compatible AlarmNet communicator.Wire Run Chart for Devices* Drawing Aux Power from the Control (12V+ & 12V–)Wire TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUNSize 50 mA or less 100 mA 300 mA 500 mA 600 mA#22 900 ft (274m) 450 ft (137m) 150 ft (46m) 90 ft (27m) 75 ft (23m)#20 1400 ft (427m) 700 ft (213m) 240 ft (73m) 140 ft (43m) 120 ft (37m)#18 1500 ft (457m) 1100 ft (335m) 350 ft (107m) 220 ft (67m) 170 ft (52m)#16 1500 ft (457m) 1500 ft (457m) 550 ft (168m) 350 ft (107m) 270 ft (82m)* Includes Keypads, RF Receivers, Zone Expander/Relay Units, and Communication Device.Maximum wire lengths for any device that is homerun to the control can also be determined from the Wiring Run Chart, based on thecurrent draw of that device alone.The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad conductor cable is used(750 feet if shielded cable is used). This restriction is due to the capacitive effect on the data lines when quad cable is used.Table of Device AddressesThis Device Uses Address Reports as†† Enabled By…RF Receiver 00 100 *56 zone programming: input device type entryAUI 1 (touchscreen) 01 automatic if AUI enable field *189 enabled for AUI 1AUI 2 (touchscreen) 02 automatic if AUI enable field *189 enabled for AUI 2AUI 3 (touchscreen) (V20P) 05 automatic if AUI enable field *189 enabled for AUI 3AUI 4 (touchscreen) (V20P) 06 automatic if AUI enable field *189 enabled for AUI 4Communication Device (LRR) 03 103 automatic if communication device is enabled in field *29Zone Expanders (4219/4229):Module 1 (for zones 09 - 16)Module 2 (for zones 17 - 24)Module 3 (for zones 25 - 32)Module 4 zones 33 - 40Module 5 zones 41 - 4807**0809†10†11†107108109110111*56 zone programming: input device type, entry 2, then:automatic if zone no. 9-16 set as AW type or relay assignedautomatic if zone no. 17-24 set as AW type or relay assignedautomatic if zone no. 25-32 set as AW type or relay assignedautomatic if zone no. 33-40 set as AW type or relay assignedautomatic if zone no. 41-48 set as AW type or relay assignedRelay Modules (4204):Module 1Module 2Module 3Module 4121314†15†112113114115*79 output device programming: device address prompt:entered at device address promptentered at device address promptentered at device address promptentered at device address promptKeypads:Keypad 1Keypad 2Keypad 3Keypad 4Keypad 5Keypad 6Keypad 7Keypad 81617181920212223n/an/an/an/an/an/an/an/adata field programming as listed below:always enabled for partition 1, all sounds enabled.data field *190data field *191data field *192data field *193data field *194data field *195data field *196RIS Communication 25 n/a automatic** address 07 not available if zone-doubling enabled† 4219/4229 addresses 9-11 and 4204 addresses 14-15 apply to the VISTA-20P.†† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable devicereporting (default = reports enabled). See field *199 for addressable device 3-digit/2-digit identification keypad display options.