1514ELECTRODESHI 1048B Glass body, double junction, refillable pH electrode withBNC connector and 1 m (3.3') cable, for wine, must andgrape juiceFC 100B PVDF body, double junction, refillable, pH electrode withBNC connector and 1 m (3.3') cable, for food industryFC 200B PVDF body, open junction, conic tip, Viscolene, non-refillablepH electrode with BNC connector and 1 m (3.3') cable, formeat & cheeseFC 210B Glass body, double junction, conic tip, Viscolene, non-refillable pH electrode with BNC connector and 1 m (3.3')cable, for milk and yogurtHI 3131B Glass body, refillable, platinum ORP electrodeHI 3230B Plastic body, gel-filled, platinum ORP electrodeHI 4430B Plastic body, gel-filled, gold ORP electrodeOTHER ACCESSORIESHI 710005 115 Vac/12 Vdc power adapter, US plugHI 710006 230 Vac/12 Vdc power adapter, European plugHI 76405 Electrode holderHI 8427 pH and ORP electrode simulator with 1 m (3.3') coaxialcable ending in female BNC connectorsHI 931001 pH and ORP electrode simulator with LCD and 1 m (3.3')coaxial cable ending in female BNC connectorsHI 98501 Pocket-size thermometer (range -50.0 to 150.0°C)Recommendations for UsersBefore using this product, make sure that it is entirely suitable for the environment in which it is used.Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipment, requiring theoperator to take all necessary steps to correct interferences.The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times.During calibration of instruments, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostaticdischarge.To maintain the EMC performance of this equipment, the recommended cables noted in the user's manual must be used.Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance.To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 Vac or 60 Vdc.To avoid damage or burns, do not perform any measurement in microwave ovens.WARRANTYAll Hanna Instruments meters are guaranteed for two years against defectsin workmanship and materials when used for their intended purpose andmaintained according to instructions.Electrodes and probes are guaranteed for a period of six months.This warranty is limited to repair or replacement free of charge.Damages due to accident, misuse, tampering or lack of prescribed maintenanceare not covered.If service is required, contact the dealer from whom you purchased theinstrument. If under warranty, report the model number, date of purchase,serial number and the nature of the failure. If the repair is not covered by thewarranty, you will be notified of the charges incurred. If the instrument is to bereturned to Hanna Instruments, first obtain a Returned Goods Authorizationnumber from the Customer Service department and then send it with shippingcosts prepaid. When shipping any instrument, make sure it is properlypackaged for complete protection.All rights are reserved. Reproduction in whole or in part is prohibitedwithout the written consent of the copyright owner.Hanna Instruments reserves the right to modify the design, construction andappearance of its products without advance notice.