Hanna Instruments HI 99181 Instruction Manual
Also see for HI 99181: Instruction manualInstruction manualInstruction manual
w w w . h a n n a i n s t . c o mRange -2.00 to 16.00 pH-5.0 to 105.0°C / 23.0 to 221.0°FResolution 0.01 pH / 0.1°C / 0.1°FAccuracy ±0.02 pH(@20°C/68°F) ±0.5°C up to 60°C; ±1.0°C outside±1.0°F up to 140°F; ±2.0°F outsideTypical EMC ±0.02 pHDeviation ±0.2°C or ±0.4°FTemperature Compensation AutomaticpH Calibration Automatic, 1 or 2 pointchoose between 2 sets of buffers(standard: 4.01/7.01/10.01 or NIST: 4.01/6.86/9.18)Probe (included) HI 1414D/50preamplified pH/temperature probeBattery Type 3 x 1.5V AAABattery Life Approximately 1200 hours of continuous useInstruction ManualHI 99181Portable WaterproofSkin pH MeterDear Customer,Thank you for choosing a Hanna Instruments Product.Please read this instruction manual carefully before using theinstrument. If you need additional technical information, do nothesitate to e-mail us at tech@hannainst.com.All Hanna Instruments meters are warranted for two yearsagainst defects in workmanship and materials when used fortheir intended purpose and maintained according to instructions.The probes are warranted for a period of six months.This warranty is limited to repair or replacement free of charge.Damage due to accidents, misuse, tampering or lack ofprescribed maintenance are not covered.If service is required, contact the dealer from whom youpurchased the instrument. If under warranty, report the modelnumber, date of purchase, serial number and the nature of theproblem. If the repair is not covered by the warranty, you willbe notified of the charges incurred. If the instrument is to bereturned to Hanna Instruments, first obtain a Returned GoodsAuthorization Number from the Customer Service departmentand then send it with shipment costs prepaid. When shippingany instrument, make sure it is properly packaged for completeprotection.All rights are reserved. Reproduction in whole or in part is prohibitedwithout the written consent of the copyright owner.Remove the instrument from the packing material and examineit carefully to make sure that no damage has occurred duringshipment. If noticeable damage is evident, notify your dealer.Note: Save all packing material until you are sure that theinstrument functions correctly. All defective items must bereturned in the original packing together with thesupplied accessories.HI 99181 is a portable, microprocessor-based pH andtemperature meter with a special flat surface probe.The HI 1414D/50 probe has been specially designed with a flattip for skin pH measurement.Moreover, a built-in temperature sensor allows simultaneoustemperature compensated pH and temperature readings andan integral pH sensor preamplifier provide measurementsimpervious to noise and electrical interferences.The meter is supplied with:• HI 1414D/50 pH/temperature probe with flat tip,50 mm-long body, DIN connector and 1m (3.3’) cable• HI 700621 Cleaning solution for skin grease and sebum,20 mL sachet (2 pcs.)• Calibration and cleaning solution sachets• 3 x 1.5V AAA batteries• Instruction manual.Hanna Instruments reserves the right to modify the design,construction and appearance of its products without advancenotice.HI 1414D/50 Preamplified pH probe with flat-tip 50 mm-longbody, built-in temperature sensor, DIN connectorand 1 m (3.3’) cableHI 70004P pH 4.01 buffer solution, 20 mL sachet (25 pcs.)HI 7004L pH 4.01 buffer solution, 500 mL bottleHI 70006P pH 6.86 buffer solution, 20 mL sachet (25 pcs.)HI 7006L pH 6.86 buffer solution, 500 mL bottleHI 70007P pH 7.01 buffer solution, 20 mL sachet (25 pcs.)HI 7007L pH 7.01 buffer solution, 500 mL bottleHI 70300M pH electrode Storage solution, 230 mL bottleHI 70300L pH electrode Storage solution, 500 mL bottleHI 7061M pH electrode General purpose cleaning solution,230 mL bottleHI 7061L pH electrode Cleaning solution, 500 mL bottleHI 700620P Cleaning & disinfection solution for removal ofskin residuals, 20 mL sachet (25 pcs.)HI 70620M Cleaning & disinfection solution for removal ofskin residuals, 230 mL bottleHI 70620L Cleaning & disinfection solution for removal ofskin residuals, 500 mL bottleHI 700621P Cleaning solution for removal of skin grease andsebum, 20 mL sachet (25 pcs.)HI 70621M Cleaning solution for removal of skin grease andsebum, 230 mL bottleHI 70621L Cleaning solution for removal of skin grease andsebum, 500 mL bottleHI 70960 Electrolyte solution for sample preparation,30 mL bottleHI 76405 Electrode holder1. Automatic Temperature Compensation indicator2. Battery percentage (visible at power up)3. Secondary display4. Low battery indicator5. Stability indicator6. pH calibration indicator7. Selectable temperature unit8. Primary display9. Measuring unit for primary displayIST99181Z 01/11Auto-off After 8 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max. 100%Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)Weight 205 g (7.2 oz.)WARRANTY GENERAL DESCRIPTIONSPECIFICATIONSPRELIMINARY EXAMINATIONLCD DESCRIPTIONACCESSORIES |
Related manuals for Hanna Instruments HI 99181
Hanna Instruments HI 99181 Instruction Manual
Hanna Instruments HI99181 Instruction Manual
Hanna Instruments HI99181 Instruction Manual
Hanna Instruments HI 99163 Instruction Manual
Hanna Instruments HI 99171 Instruction Manual
Hanna Instruments HI 99131 Instruction Manual
Hanna Instruments HI 99141 Instruction Manual
Hanna Instruments HI 99161 Instruction Manual
Hanna Instruments HI 99191 Instruction Manual
Hanna Instruments HI 99131 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved